Zones and devices
Building Technologies
HVAC Products
7

Communication via zone addresses

7.1

General notes on zones

7.1.1

Synco zoning

Zoning in Synco is based on KNX and covers the following zones for Synco 700
devices and RXB/RXL room controllers:
Designation
Geographical zone (apartm)
Geographical zone (room)
Geographical zone (subzone)
Time switch zone (apartment)
Time switch zone (room)
Time switch zone (subzone)
Time switch slave (apartment)
Master/slave zone (apartment)
Master/slave zone (room).
Master/slave zone (subzone)
QAW op.zone (apartment)
Heat distribution zone
Heat distr zone source side
Heat distr zone consumer side
Heat distr zone heating surface
Heat distribution zone air heater
Heat distrib. zone, primary distr.
Heat distrib. zone, primary contr.
Refrigeration distribution zone
Refrig distr zone source side
Refrig distr zone consumer side
Refrig distr zone cooling surface
Refrig distrib. zone cooling coil
Air distribution zone
Boiler sequencing zone
DHW zone
Holiday/special day zone
Time switch, DHW slave
Outside temperature zone
Solar zone
Wind zone
---- / 1 Depending on the device, the default is "----" (e.g. RMU7x0B) or "1" (e.g. RMU7x0).
See also section 7.1.4 for information on the default "----" with the series B devices.
----
With RXB/RXL room controllers "----" indicates that the zone is "out of service" and there are no
process values transmitted from this zone (in the QAX34.3 room device, "-1" is displayed
instead of "----".
*
The zone address range for the RXB/RXL room controllers is 0...63 or 0...15.
Basic documentation: Communication via the KNX bus
Communication via zone addresses
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
Zone
Def'
Def.
address
value
value
range
RM...
RX...
x
1...126
---- /1
x
1...63 *
---- /1
x
1...15 *
x
1...126
x
1...63 *
x
1...15 *
1...126
---- /1
x
1...126
x
1...63 *
x
1...15 *
1...126
----
1...31
1
1...31
----
1...31
1 / 2
x
1...31
x
1...31
1...31
1
1...31
2
1...31
1
1...31
----
1...31
---- /1
x
1...31
x
1...31
1...31
1
1...16
1
1...31
1
1...31
---- /1
1...31
1
x
1...31
---- /1
1...31
----
1...31
----
CE1P3127en
30.08.2007
----
1
1
1
1
1
1
----
1
----
----
----
----
1
67/120