Epson M200 Series Service Manual page 57

Color
Hide thumbs Also See for M200 Series:
Table of Contents

Advertisement

M200 / M205 / M100 / M105 Series
Panel FFC (M200/M205 Series)
Panel FFC
Main Frame
Frame Base
Housing Front
Double-sided tape
Route the Frame Base and Main Frame along the folded line and secure
with the double-sided tape on the position shown in the above.
After installing the Housing Front, route the Panel FFC through the hole
of the Housing Front.
Left side of Main Board (M200/M205 Series)
M200 Series
FFC Holder MB
Ferrite core
PF Motor cable
Panel FFC
Ethernet Board cable
PS Unit cable
PF Encoder FFC
Connect the following cables/FFCs to the Main Board as shown above.
• PF Motor cable (CN13)
• Wireless LAN Module Cable (CN4: only for M205 Series)
• Ethernet Board cable (CN14: only for M200 Series)
• Panel FFC (CN2) : Secure the ferrite core of the FFC Holder MB and connect to the Main Board through the ferrite core.
Disassembly/Reassembly
Panel Unit (M200/M205 Series)
Connector of
Panel Board
Main Frame
Panel FFC
Hole
Grounding wire
C.B.S-TITE SCREW 3x6 F/ZN-3C (6 ± 1 kgf·cm)
Route the Panel FFC and grounding wire as follows before installing the
Panel Unit.
Route the Panel FFC through the hole of the Panel Unit and connect the
connector of the Panel Board.
Route the grounding wire through the hole of the Housing Front.
After installing the Panel Unit, secure the grounding wire to the Main
Frame on the position indicated in the figure above with screw (x1).
M205 Series
FFC Holder MB
Ferrite core
PF Motor cable
PS Unit cable
Wireless LAN Module Cable
• PS Unit cable (CN501)
• PF Encoder FFC (CN7)
Panel FFC (M100/M105 Series)
Hole
Frame Base
Panel Unit
Housing Front
Housing Upper Assy
Route the Panel FFC through the rib of the Frame Base and Main Frame
along the folded line and secure with the double-sided tape on the position
shown above.
Route through the hole of the Housing Upper Assy and secure with the
double-sided tape on the position shown above.
M100 Series
Panel FFC
PF Motor cable
PF Encoder FFC
Ethernet Board cable
Connect the following cables/FFCs to the Main Board as shown above.
• PF Motor cable (CN13)
• Wireless LAN Module Cable (CN4: only for M105 Series)
• Ethernet Board cable (CN14: only for M100 Series)
Routing FFCs/cables
Panel FFC
Main Frame
Hole
Panel FFC
Rib
Double-sided tape
Connect the following cables/FFCs to the Main Board as shown in the figure
above.
Left side of Main Board (M100/M105 Series)
M105 Series
Panel FFC
PS Unit cable
PF Encoder FFC
• PS Unit cable (CN501)
• PF Encoder FFC (CN7)
• Panel FFC (CN2)
Revision A
Right side of Main Board
CN102
CN61
CR Motor cable
Main Board
Double-sided tape
Head FFC
CN12
CR Encoder FFC
CR Motor cable (CN12)
CR Encoder FFC (CN6)
Head FFC (CN102)
Secure with the double-sided tape on the position shown above.
Panel FFC
PF Motor cable
Wireless LAN Module Cable
PS Unit cable
PF Encoder FFC
Confidential