Sharp KSH-Q11 Service Manual page 8

Automatic rice cooker
Table of Contents

Advertisement

1. Remove the bottom lid in accordance with "REMOVE OF BOTTOM LID".
2. Remove the closed terminal holding for the neon lamp lead wires.
3. Cut the cord band and disconnect terminal from the micro SW.
4. Remove 2 screws holding the lead wire yellow and lead wire blue from
2 heater terminals and disconnect terminal from the micro switch.
5. Remove the screw holding the panel from the outer pot.
6. Pull the insulator cover from the panel.
7. Remove the neon lamp ass'y from the panel.
8. Now the neon lamp ass'y is free.
Panel
1. Remove the bottom lid in accordance with "REMOVE OF BOTTOM LID".
2. Remove 2 screws holding lead wires from the heater plate ass'y.
3. Remove 3 screws holding the heater plate ass'y from the reflector.
4. Now the heater plate ass'y is free.
REMOVE OF NEON LAMP ASSEMBLY
Insulator
Neon lamp ass'y
REMOVE OF HEATER PLATE ASSEMBLY
Heater plate
Outer pot
Screw
Outer pot
Fig. 9
Screw
Fig. 10
Screw
8
Micro switch
Lead wire yellow
Lead wire red
Terminal
Closed terminal
Cord band
Lead wire yellow
Lead wire blue
Screw
Reflector
Screw
Heater
terminal
Screw

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ksh-q18Ksh-candy 11Ksh-candy 18

Table of Contents