Ventilation Recommendations
Installation Procedure
Apply Foam Tape
Install Backwall Trim
1. Adjust height of range and level by rotating the adjustable leg supports on the
bottom of the range, using 1-1/4" wrench.
2. Measure to locate bracket position as shown in See Figure 5: Anti-Tip
Bracket.
3. Secure bracket with 2 screws adequate for mounting surface (i.e., for wood
floor use wood screws, for concrete floor use concrete anchors and screws).
We strongly recommend the installation of a ventilation hood above this appli-
ance. For most kitchens a certified hood rating of not less than 300 CFM is recom-
mended. The range hood must be installed according to instructions furnished
with the hood.
Apply foam tape to underside of cooktop trim in one continuous piece.
Note: DO NOT use caulk or glue/adhesive of any kind.
Note: This step is only required if the countertop does not connect behind the
range (i.e.; when replacing a free-standing range). See "Cabinet Requirements"
on page 6 for more information
rear wall
cabinet wall
flush against
cabinet wall
1 9/16" (39.7 mm)
from rear wall to center of screw hole
floor
anti-tippin g
device
Figure 5: Anti-Tip Bracket