Embedded Consoles - All Versions - Star Trac 8-TRx Service Manual

Core health & fitness
Hide thumbs Also See for 8-TRx:
Table of Contents

Advertisement

Embedded Consoles - All Versions

Error
Name
Code
1
ERR_DISP_WATCHDOG_TIMEOUT
2
ERR_XCB_WATCHDOG_TIMEOUT
3
ERR_DISP_READY_TIMEOUT
4
ERR_DISP_QRYID_RESP_TIMEOUT
5
ERR_ALL_QRYID_RESP_TIMEOUT
6
ERR_XCB_QRYID_RESP_TIMEOUT
ERR_INVALID_SYSTEM_COMBINA-
7
TION,
8
ERR_GUI_QUEUE_CREATE
9
ERR_FIT_FIFO_OPEN
Description
Display watchdog timeout. This is
reported when there is no communi-
cation between the Display and the
FitCPU for more than 2 seconds.
XCB watchdog timeout. This is report-
ed when there is no communication
between the FitCPU and the xCB for
more than 2 seconds.
Timeout waiting for touch display
ready. This is reported when the
FitCPU does not receive a touch ready
message from the display during boot
up.
Timeout waiting for query id response
from display. This is reported when
the FitCPU does not receive a query
id response from the display during
boot up.
No query id response received from
display or XCB. This is reported when
the FitCPU does not receive a query
id response from both the display and
xCB during boot up.
Timeout waiting for query id response
from XCB. This is reported when the
FitCPU does not receive a query id
response from the xCB during boot up.
Invalid display and XCB combination.
This is reported when the FitCPU
detects an invalid display and xCB
combination during boot up.
Error creating GUI queue. This is
reported when the computer has an
internal error during boot up.
Error opening Fit FIFO. This is reported
when the computer has an internal
error during boot up.
Diagnosis
1) Re-boot the unit and see if the prob-
lem goes away .
2) If the problem persists, check the
comms cable between the FitCPU and
the Display .
3) If the problem still persists change
the comms cable.
1) Re-boot the unit and see if the prob-
lem goes away .
2) If the problem persists, check the
comms cable between the FitCPU and
the xCB .
3) If the problem still persists change
the comms cable.
(This error is currently disabled and will
not be seen on any units)
1) Re-boot the unit and see if the prob-
lem goes away .
2) If the problem persists, check the
comms cable between the FitCPU and
the Display .
3) If the problem still persists change
the comms cable.
1) Re-boot the unit and see if the prob-
lem goes away .
2) If the problem persists, check the
comms cables between the FitCPU and
the Display and xCB .
3) If the problem still persists change
both of the comms cable.
1) Re-boot the unit and see if the prob-
lem goes away .
2) If the problem persists, check the
comms cable between the FitCPU and
the xCB .
3) If the problem still persists change
the comms cable.
(This error is currently disabled and will
not be seen on any units)
1) Re-boot the unit and see if the prob-
lem goes away .
2) If the problem persists, replace the
computer.
1) Re-boot the unit and see if the prob-
lem goes away .
2) If the problem persists, replace the
computer.
Command
Used
FIT_ERROR
FIT_ERROR
FIT_ERROR
FIT_ERROR
FIT_ERROR
FIT_ERROR
FIT_ERROR
DISP_ERROR
DISP_ERROR
Page 44

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

8-trE-trxE-trxeE-trxiE-trE-tri ... Show all