Figure 1 Multi-Tec Wall-Mount Unit Model Nomenclature - Bard MULTI-TEC W42ACE Series Service Instructions Manual

Wall-mount air conditioner
Table of Contents

Advertisement

Last 24 Hour Tracking ...................... 8
Last 24 Hour Tracking ...................... 8
Figure 10 Unit Configuration ........................... 9
Figure 11 Executing Self Test ........................ 10
Figure 14 Clearing Alarms ............................. 11
Figure 15 Clearing Alarm Logs ....................... 11
Figure 19 Blower Speeds .............................. 14
Figure 25 Economizer A4 Screen ................... 17
Figure 26 Economizer A5 Screen ................... 17
Values .......................................... 17
Module ......................................... 25
Figure 32 Fan Blade Setting .......................... 26
W
42
MODEL SERIES
CAPACITY
42 - 3½ Ton
48 - 4 Ton
60 - 5 Ton
72 - 6 Ton
A - A/C
E - PLC Logic Board w/Electric Reheat
M - PLC Logic Board w/Mechanical Dehumidification 
A - 230/208/60/1
B - 230/208/60/3
C - 460/60/3
D - 240/220/50/1
 Reference Supplemental Instructions 7960-864
for complete details.
 Having "B" in this position in the model number
disables all economizer function. Emergency vent will
still operate when "B" is in this position.
MULTI-TEC W42-72AC Wall-Mount Unit Model Nomenclature
A
C
P
A
REVISION
P - PLC Logic Board
VOLTS & PHASE
E - 240/220/50/3
or 220/200/50/3
F - 415/380/50/3
Q - 575/60/3
KW
VENTILATION OPTIONS
B - Blank-off Plate 
5 or E - Economizer
Figure 34 Removing Left Filter ...................... 29
Figure 37 Bend Filter Tabs Down ................... 29
Figure 38 Remove Four Screws ...................... 30
into Lower Slots ............................. 30
Figure 41 Install Right 2" Filter ..................... 30
Figure 42 Install Left 2" Filter ....................... 30
Figure 44 Adjusting Filter Switch ................... 32
Figure 45 Motor Connections ......................... 33
Figure 46 Motor Connections ......................... 34
Table 1
LC1000/TEC-EYE Passwords
(Defaults) ....................................... 7
Table 2
Wall-Mount Unit Status Messages ..... 7
Table 3
Software Versioning Guide ................ 9
Table 4
Unit Control Board Terminals .......... 21
Table 5
MULTI-TEC Cooling Pressures ......... 23
Table 6
W42-72AC* Optional Accessories ... 27
Table 7
8301-067 Sensor: Temperature/
Resistance .................................... 36
Table 8
8301-067 Sensor: Humidity/Voltage .. 37
Table 9
Resistance Curve J ......................... 38
Table 10
Wall-Mount Unit Alarm Index .......... 39
FIGURE 1
10
5
X
X
FILTER OPTIONS
X - 1" Throwaway (Standard)
W - 1" Washable
P - 2" Pleated (MERV 8)
X
X
E
CONTROL MODULES
E - Low Ambient Control
C - Low Ambient Control
& Crank Case Heater
COIL OPTIONS
X - Standard
1 - Phenolic Coated Evaporator
2 - Phenolic Coated Condenser
3 - Phenolic Coated Evaporator
and Condenser
4 - Coated Coils and Condenser
Section
5 - Coated Coils, Inside and
Outside of Unit
PLACEHOLDER
X for future use
COLOR OPTIONS
X - Beige (Standard)
8 - Dark Bronze
1 - White
S - Stainless Steel
A - Aluminum
4 - Buckeye Gray
5 - Desert Brown
M - 2" Pleated (MERV 11)
N - 2" Pleated (MERV 13)
Manual 2100-725C