Recommended Grounding Method - Whirlpool Microwave Oven Installation Instructions Manual

30” eye-level gas microwave range and 30” eye-level gas range
Hide thumbs Also See for Microwave Oven:
Table of Contents

Advertisement

D. Electrical requirements -
Conventional
Eyelevel
A 120 Volt, 60 Hz, AC only, 15 Ampere fused electrical
supply is required (time delay fuse or circuit breaker
is recommended).
It is recommended
that a separate
circuit serving only this appliance be provided. DO NOT
use an extension
cord.
The wiring diagram is located on the storage drawer.
1. Recommended grounding method
For your personal
safety,
electrical
ground
is re-
quired
on this appliance.
DO NOT, UNDER ANY CIRCUMSTANCES,
CUT OR
REMOVE
THE POWER SUPPLY
CORD GROUND
PRONG.
This appliance
is equipped with a power supply cord
having a 3-prong grounding
plug. To minimize possi-
ble shock hazard, the cord must be pluged into a
mating 3-prong grounding type wall receptacle, ground-
ed in accordance with the National Electrical Code, AN-
SllNFPA
NO. 70-l 981
l
* and local codes and or-
dinances.
If a mating wall receptacle
is not available,
it is the personal responsibility
and obligation
of the
customer to have a properly grounded
3-prong wall
receptacle
installed
by a qualified
electrician.
XPRONG
GROUNDING
TYPE
WALL
RECEPTACLE
NG
NDING
\
POWER
SUPPLY
CORD
FIG. 3
**Copies of the standard listed above may be obtained from:
NATIONAL
FIRE PROTECTION
ASSOCIATION
Batterymarch Park
Quincy, Massachusetts 02269
Check the polarity of the receptacle before plug-
ging in. See "Alternate
Grounding
Method."
2. Alternate grounding method
If changing and properly grounding the wall receptacle
is impossible
and where local codes permit (consult
your electrical inspector), a temporary adapter may be
plugged
into the existing
2-prong wall receptacle
to
mate with the 3-prong power supply cord. See below.
FIG. 4
3.PRONG
GAOUNDING
PLUG
GROUND
ASSEMBLY
(ATTACH
TOGROUNDED
METAL
COLD
WATER
PIPE)
ELECTRICALLY
-
GROUNDED
METAL
OUND
PRONG
POWER
SUPPLY
CORD
*Cold water pipe must have metal continuity
to elec-
trical ground and not be interrupted
by plastic, rubber
or other electrically
insulating
connectors
(including
water meter or pump) without adding a jumper wire at
these connections.
E. Electrical requirements -
Eyelevel Mi&owave
A 120 Volt, 60 Hz, AC only, 20 Ampere fused electrical
supply is required (time delay fuse or circuit breaker
is recommended).
It is recommended
that a separate
circuit serving only this appliance be provided. DO NOT
use an extension
cord.
The wiring diagram (Tech Sheet) is located inside the
control panel area.
1. Recommended grounding method
For your personal
safety,
electrical
ground
is re-
quired
on this appliance.
5