11. ERROR CODE LIST

Error code
Pictograph
E001
E007
E011
E012
E013
E014
E015
E016
E017
E018
Description of error
Contact of EEP-ROM initialization of MAIN
CONTROL p.c.b.
When data is not written in EEP-ROM or data is
broken, data is automatically initialized and the
initialization is informed.
Main shaft motor-lock
When large needle resistance sewing product
is sewn
External media not inserted
External media is not inserted.
Read error
Data read from external media cannot be performed. recover by reset.
Write error
Data write from external media cannot be performed. recover by reset.
Write protect
External media is in the write prohibition state
Format error
Formatting of external media cannot be performed.
External media capacity over
Capacity of external media is short.
EEP-ROM capacity over
Capacity of EEP-ROM is short.
Type of EER-ROM is different
When the mounted EEP-ROM is different in type.
– 129 –
How to recover
Place of recovery
Turn OFF the
power.
Turn OFF the
power.
Possible to
recover by reset.
Possible to
Previous screen
Possible to
Previous screen
Possible to
Previous screen
recover by reset.
Possible to
Previous screen
recover by reset.
Possible to
Previous screen
recover by reset.
Possible to
Previous screen
recover by reset.
Turn OFF the
Previous screen
power.