Error Code List - JUKI MO-6800S/DD20 Series Instruction Manual

Table of Contents

Advertisement

9. ERROR CODE LIST

Error code
E01
Overvoltage error
E02
Low voltage error
E03/E03P
Communication fault between the operation panel and the electrical box
E05
Pedal signal fault
Lock error
E07
This error is automatically reset when the pulley is turned.
E09
Upper stop position cannot be found during operation.
E10
Solenoid current is excessively large.
E11
Upper stop position cannot be found after the power is turned ON.
E14
Encoder signal or hall signal is not normal.
E15
Hardware overcurrent signal (fault signal)
E16
The presser foot is not placed in its correct position.
E17
The cloth plate cover is not placed in its correct position.
E18
The eye protection cover is not placed in its correct position.
E19
Electrolytic capacity connection error
E21
The operation panel PCB has re-started.
E41
There is no MAIN software program.
E42
There is no SUB software program.
E44
There is no voice software.
If there is no operation panel software program, "----" will be displayed.
Only for errors E16, E17 and E18, return the relevant parts to their correct positions and press
on the operation panel. Then, the sewing machine will be reset and return to its normal
state. Be sure to check that there is no obstacle that may block the sensors before pressing
. If any of the sensor is blocked, the sewing machine may run suddenly.