9. ERROR CODE LIST

Error code
Overvoltage error
E01
This error code is displayed when the alternating-current voltage
exceeds 317 V - 325 V.
Low voltage error
E02
This error code is displayed when the alternating-current voltage
drops below 170 V.
Communication fault between the operation panel and the electrical
E03
box
E05
Pedal signal fault
Lock error
E07
This error is automatically reset when the pulley is turned.
E09
Upper stop position cannot be found during operation.
E14
Encoder signal or hall signal is not normal.
E15
Hardware overcurrent signal (fault signal)
E19
Electrolytic capacitor connection error
E21
The operation panel PCB has re-started