JUKI AMB-289 Engineer's Manual page 134

Computer-controlled, high-speed, single thread, chainstitch, button-neck-wraping machine
Hide thumbs Also See for AMB-289:
Table of Contents

Advertisement

Error code
Pictograph
E019
E022
E023
E024
E027
E028
E029
E030
E031
E042
Description of error
File size over
File siza to be read in is too large.
File No. error
There is no designated file in the server or external
media.
Detection of step-out of presser lifting
motor error
When step-out of motor is detected at the time
when presser lifting motor passes the origin sensor.
Pattern data size over
When sewing cannot be performed since the size
of downloaded sewing data is too large.
Read error
Data read from server cannot be performed.
Write error
Data write to the server cannot be performed.
Smart media slot release error
Lid of smart media slot is open.
Needle bar upper position failure
When needle does not stop at UP position at the
time of needle UP operation.
Air pressure drop
When air pressure dropped.
Operation error
Operation of sewing data cannot be performed.
– 130 –
How to recover
Place of recovery
Possible to
Previous screen
recover by reset.
Possible to
Previous screen
recover by reset.
Possible to
Data input screen
recover by reset.
Possible to
Data input screen
recover by reset.
Possible to
Previous screen
recover by reset.
Possible to
Previous screen
recover by reset.
Possible to
Previous screen
recover by reset.
Possible to
Data input screen
recover by reset.
Possible to
Data input screen
recover by reset.
Possible to
Data input screen
power.

Advertisement

Table of Contents
loading

Table of Contents