PROPANE AND HIGH ALTITUDE CONVERSION KITS
It is very important to choose the correct kit and/or gas orifices for the altitude and the type of gas for which the furnace is being installed.
Only use natural gas in furnaces designed for natural gas. Only use propane (LP) gas for furnaces that have been properly converted to use pro-
pane (LP) gas. Do not use this furnace with butane gas.
Incorrect gas orifices or a furnace that has been improperly converted will create an extremely dangerous condition resulting in premature heat
exchanger failure, excessive sooting, high levels of carbon monoxide, personal injury, property damage, a fire hazard and/or death.
High altitude and propane (LP) conversions are required in order for the appliance to satisfactory meet the application.
An authorized distributor or dealer must make all gas conversions.
In Canada, a certified conversion station or other qualified agency, using factory specified and/or approved parts, must perform the conversion.
The installer must take every precaution to insure that the furnace has been converted to the proper gas orifice size when the furnace is installed.
Do not attempt to drill out any orifices to obtain the proper orifice size. Drilling out a gas orifice will cause misalignment of the burner flames, caus-
ing premature heat exchanger burnout, high levels of carbon monoxide, excessive sooting, a fire hazard, personal injury, property damage and/or
death.
SECTION V: ELECTRICAL POWER
ELECTRICAL POWER CONNECTIONS
CAUTION
!
Use copper conductors only.
Table 6: Ratings & Physical / Electrical Data
Input
High/Low
Model
MBH
TM9V040A10
40/26
TM9V060B12
60/39
TM9V080B12
80/52
TM9V080C16
80/52
TM9V100C16
100/65 29/19
TM9V100C20
100/65 29/19
TM9V120D20
120/78 35/23 115/75 33/22
Max. Outlet
Air Temp.
Model
°F
TM9V040A10
190
TM9V060B12
190
TM9V080B12
190
TM9V080C16
190
TM9V100C16
190
TM9V100C20
190
TM9V120D20
190
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
The furnace shall be installed so that the electrical components are protected from water.
Johnson Controls Ducted Systems
!
Output
Nominal
High/Low
Airflow
kW
MBH
kW
CFM
12/8
38/25
11/7
1000
18/11
58/37
17/11
1200
23/15
77/50
22/14
1200
23/15
77/50
22/14
1600
96/62
28/18
1600
96/62
28/18
2000
2000
Blower
Blower Wheel Size AFUE
°C
HP
Amps inches
88
1/2
7.7
11 x 8 27.9 x 20.3
88
1/2
7.7
11 x 8 27.9 x 20.3
88
1/2
7.7
11 x 8 27.9 x 20.3
88
3/4
9.6
11 x 10 27.9 x 25.4
88
3/4
9.6
11 x 10 27.9 x 25.4
88
1
12.8
11 x 11 27.9 x 27.9
88
1
12.8
11 x 11 27.9 x 27.9
DANGER
Field wiring to the unit must be grounded. Electric wires that are field
installed shall conform to the temperature limitation for 63°F (35°C) rise
wire when installed in accordance with instructions. Refer to Table 6 in
these instructions for specific furnace electrical data.
Cabinet Width
3
in.
cm
m
/min
28.3
14-1/2
36.8
34
17-1/2
44.4
34
17-1/2
44.4
45.3
21
53.3
45.3
21
53.3
56.6
21
53.3
56.6
24-1/2
62.2
Total
Unit
Amps
cm
%
96
9.6
96
9.6
96
9.6
96
11.5
96
11.5
96
14.7
96
14.7
5750149-UIM-D-1219
High Fire
Air Temp. Rise
°F
°C
30 - 60
17-33
35 - 65
19-36
40 - 70
22-39
35 - 65
19-36
35 - 65
19-36
35 - 65
19-36
35 - 65
19-36
Recommended
Gas Pipe
Fuse or
Connection,
Circuit Breaker
NPT
Amps
15
1/2"
15
1/2"
15
1/2"
15
1/2"
15
1/2"
20
1/2"
20
1/2"
Low Fire
Air Temp. Rise
°F
°C
20 - 50 11-28
35 - 65
19-36
35 - 65
19-36
35 - 65
19-36
30 - 65
17-33
35 - 65
19-36
35 - 65
19-36
Operating
Weight
Lbs.
kg.
113
51.2
122
55.3
126
57.1
136
61.7
142
64.4
145
65.7
156
70.7
11

Advertisement

Table of Contents
loading

Table of Contents