Gas Rate (Cu Ft/Hr) At Full Input; Inlet Gas Pressure Range - Johnson Controls TM9V C Series Installation Manual

Two stage variable speed ecm residential gas furnaces
Table of Contents

Advertisement

5750149-UIM-D-1219
Table 15: Gas Rate (CU FT/HR) at Full Input
Seconds For
1 Revolution
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
ADJUSTMENT OF MANIFOLD GAS PRESSURE &
INPUT RATE
Inlet and manifold gas pressure may be measured by connecting the
"U" tube manometer to the gas valve with a piece of tubing. Follow the
appropriate section in the instructions below. Refer to Figure 39 for the
locations of the pressure ports on the gas valve.
Turn gas off at the ball valve or gas cock on gas supply line
before the gas valve. Find the pressure ports on the gas
valve marked Out P and In P.
1. The manifold pressure must be taken at the port marked OUT P.
2. The gas line pressure must be taken at the port marked IN P.
3. Using a 3/32" (2.4 mm) hex head wrench, loosen the set screw by
turning it 1 turn counter clockwise. DO NOT REMOVE THE SET
SCREW FROM THE PRESSURE PORT.
32
Size of Test Dial
1 Cu Ft
2 Cu Ft
5 Cu Ft
360
720
327
655
300
600
277
555
257
514
240
480
225
450
212
424
200
400
189
379
180
360
171
343
164
327
157
313
150
300
144
288
138
277
133
267
129
257
124
248
120
240
116
232
113
225
109
218
106
212
103
206
100
200
97
195
95
189
92
185
90
180
88
176
86
172
84
167
82
164
80
160
78
157
76
153
75
150
73
147
72
144
71
141
69
138
68
136
67
133
Seconds For
1 Revolution
1800
55
1636
56
1500
57
1385
58
1286
59
1200
60
1125
62
1059
64
1000
66
947
68
900
70
857
72
818
74
783
76
750
78
720
80
692
82
667
84
643
86
621
88
600
90
581
92
563
94
545
96
529
98
514
100
500
102
486
104
474
106
462
108
450
110
439
112
429
116
419
120
409
124
400
128
391
133
383
138
375
144
367
150
360
157
355
164
346
171
340
180
333
Read the inlet gas pressure
Connect the positive side of the manometer to the IN P Tap on the gas
valve. Do not connect any tubing to the negative side of the manometer,
as it will reference atmospheric pressure. Refer to Figure 40 for connec-
tion details.
1. Turn gas and electrical supplies on and follow the operating instruc-
tions to place the unit back in operation.
Table 16: Inlet Gas Pressure Range
Minimum
Maximum
Size of Test Dial
1 Cu Ft
2 Cu Ft
65
131
64
129
63
126
62
124
61
122
60
120
58
116
56
112
54
109
53
106
51
103
50
100
48
97
47
95
46
92
45
90
44
88
43
86
42
84
41
82
40
80
39
78
38
76
38
75
37
74
36
72
35
71
35
69
34
68
33
67
33
65
32
64
31
62
30
60
29
58
28
56
27
54
26
52
25
50
24
48
23
46
22
44
21
42
20
40

INLET GAS PRESSURE RANGE

Natural Gas
4.5" w.c. (1.12 kPa)
8.0" w.c. (1.99 kPa)
10.5" w.c. (2.61 kPa)
13.0" w.c. (3.24 kPa)
Johnson Controls Ducted Systems
5 Cu Ft
327
321
316
310
305
300
290
281
273
265
257
250
243
237
231
225
220
214
209
205
200
196
192
188
184
180
178
173
170
167
164
161
155
150
145
141
135
130
125
120
115
110
105
100
Propane (LP)