1.4

Servo amplifier standard specifications

MR-JET-_G-N1

Model: MR-JET-_-N1
Output
Power supply input
Interface power supply
Control method
Dynamic brake
EtherCAT
Communication function
Protective functions
Satisfied standards
Structure (IP rating)
*2
Close mounting
Mass [kg]
*1 This value is applicable when all I/O signals are used. Reducing the number of I/O points decreases the current capacity.
*2 If closely mounting the servo amplifiers, operate them at an ambient temperature of 0 ˚C to 45 ˚C or at 75 % or less of the effective load
ratio.
*3 This current value is applicable when a 3-phase power supply is used.
*4 If using 1-phase 200 V AC to 240 V AC power supply, operate the servo amplifier at 75 % or less of the effective load ratio.
1 SPECIFICATIONS
10
1.4 Servo amplifier standard specifications
10G
Voltage
3-phase 0 V AC to 240 V AC
Rated current [A]
1.3
Voltage/Frequency
3-phase or 1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz
*3
Rated current [A]
0.9
Permissible voltage
3-phase or 1-phase 170 V AC to 264 V AC
fluctuation
Permissible
Within ±5 %
frequency
fluctuation
Power supply
Refer to "Power supply capacity and generated loss" in the following manual.
MR-JET User's Manual (Hardware)
capacity [kVA]
Inrush current [A]
Refer to "Inrush current at power-on" in the following manual.
MR-JET User's Manual (Hardware)
Voltage
24 V DC ±10 %
*1
Current capacity [A]
0.3
Sine-wave PWM control, current control method
Built-in
Communication
125 μs, 250 μs, 500 μs, 1 ms, 2 ms, 4 ms, 8 ms
cycle
USB
Connection to a personal computer or other devices (MR Configurator2-compatible)
Overcurrent shut-off, regenerative overvoltage shut-off, overload shut-off (electronic thermal), servo motor
overheat protection, encoder error protection, regenerative error protection, undervoltage protection,
instantaneous power failure protection, overspeed protection, excessive error protection, magnetic pole
detection protection, and linear servo control error protection
CE marking
LVD: EN 61800-5-1, EMC: EN 61800-3
UL standard
UL 61800-5-1
Natural cooling, open (IP20)
3-phase power
Possible
supply input
1-phase power
Possible
supply input
0.8
20G
40G
70G
1.8
2.8
5.8
1.5
2.6
3.8
1.6
100G
200G
300G
6.0
11.0
11.0
3-phase or 1-phase 200 V
3-phase 200
AC to 240 V AC, 50 Hz/60
V AC to 240
*4
Hz
V AC, 50 Hz/
60 Hz
5.0
10.5
14.0
3-phase or 1-phase 170 V
3-phase 170
*4
AC to 264 V AC
V AC to 264
V AC
Force cooling, open (IP20)
Impossible
2.1

Advertisement