7.2.2 Battery installation

(1) Q6BAT battery installation procedure
The battery connector of Q6BAT is disconnected when shipping. Connect the connector as follows.
For the service life of the battery and how to replace the battery, refer to Section 11.3.
(a) Basic model QCPU
Open the CPU module front cover.
Confirm that the battery is loaded
correctly.
Insert the battery connector into the
connector pin on the case. Be sure that
the insertion direction is correct.
(b) High Performance model QCPU, Process CPU, Redundant CPU and Universal model
QCPU
Open the CPU module bottom cover.
Confirm that the battery is loaded
correctly.
Insert the battery connector into the
connector pin on the case. Be sure that
the insertion direction is correct.
Firmly push the connector all the way.
7 - 14
Completed
Figure 7.12 Q6BAT battery installation procedure
Completed
Figure 7.13 Q6BAT battery installation procedure
CPU module
Connector
Connector
Connector
stopper
CPU module
Battery