6.
Lower the control box by pushing gently down on
8he top, to gain access to the VIB (AIF) probe (see
Figure 24).
7.
Disconnect the J1 connector on the VIB board.
(see Figure 25).
8.
The VIB (AIF) probe is connected to pins 1 & 2 on
the connector (see Figure 26). NOTE: Pin 1 is
noted by an arrow in the bottom right corner.
9.
The pins are held in with small tabs (see Figure
27).
10. Using a small object such as a small screwdriver
or paperclip, lift the tab of pins 1 and 2 to release
the pins, while gently pulling
on the wires (see Figure 28).
11. Unscrew the VIB (AIF) probe
from the frypot (see Figure
29).
12. Apply Loctite
PST56765 pipe
®
thread sealant or equivalent
to
the
replacement
threads
and
screw
replacement part into the
frypot. Ensure the probe is
flush with the inside of the
vat
prior
to
tightening.
Torque the probe to 180
inch-pounds.
13. Reverse steps 1 through 8 to
return the fryer to service.
14. Once the fryer is filled with
oil
check
for
leaks
proper operation.

1.15.9 Replacing a Gas Valve

1.
Disconnect fryer from electrical and gas supplies.
2.
Disconnect the wires from the gas valve.
3.
Disconnect any flexlines.
4.
Remove the pilot gas line fitting from the gas valve.
5.
Carefully unscrew the valve from the manifold. NOTE: Some models may have the valve attached to the
manifold by means of a pipe union. In such cases, remove the valve by uncoupling the union. Some models may
require removal of the manifold.
6.
Remove all fittings from the old gas valve and install them on the replacement valve, using Loctite
equivalent pipe thread sealant. Do not apply sealant to the first two pipe threads. Doing so will clog and damage
the gas valve.
7.
Reverse steps 2-5 to install the replacement gas valve.
8.
Reconnect the fryer to the gas supply and open the cut off valve. Apply a thick soapy solution of soapy water
around each connection to check for gas leaks and ensure there are no bubbles. Eliminate any that are found.
There should be no smell of gas.
9.
Reconnect the fryer to the electrical power supply and check for proper operation.
1.15.10 Replacing the Pilot Assembly or Trailing Pilot Assembly
1.
Remove the pilot tubing from the bottom of the pilot assembly.
2.
If the pilot is the ignition pilot, disconnect the ignition cable and the sense wire.
3.
Remove the pilot mounting screw(s) from the pilot mounting bracket and remove the pilot.
4.
Reverse the procedure to replace the pilot assembly. Disconnect fryer from electrical and
part
the
Figure 26
and
Figure 28
Figure 24
1-18
Figure 25
Figure 27
VIB (AIF) Probe