Download Print this page

Operation - Regency Mirada Owner's Manual

Advertisement

O
peratiOn
o
peratIng ButtonS on the
HI – fan high speed
MED – fan medium speed
LOW – fan low speed
FAN/OFF – fan speed off
• Range of the transmitter is approximately 25 ft.
t
rOuBleshOOting
1. If fan will not start: Check main and branch circuit breakers and/or fuses. Check line wire connections to fan and switch
housing wiring. Make sure forward/reverse switch is set to one or the other position, not stuck in between.
2. If fan is noisy: Check and make sure that all screws in motor housing are snug (but not over tight). Check that the screws
securing blade brackets to the motor are tight. Check that wire connectors in switch housing are not rattling against each other
or the interior wall of the switch housing. Check that all glassware is finger tight and that bulb(s) are well held in the sockets,
if a light kit is used. Check that the canopy is firmly attached to hanging bracket and not vibrating against ceiling.
3. If fan wobbles: Check that all blades are firmly screwed into blade arms. Check that all blade arms are firmly secured to the
motor. Make sure that the light kit (if present) is firmly attached to switch housing and that all glassware and shades are
fastened properly. Wobble can also result from even the smallest deviations in distance from blade tip to blade tip - if
measurements from blade tip to blade tip are not equal, loosen screws connecting blade to bracket one at a time and adjust
blade(s) so that distances are equal. Interchanging adjacent blades may redistribute mass and result in smoother operation.
Blade arms can be bent slightly to restore same pitch to all blades if a blade is different than the other blades when viewed
edge on.