Chapter 8. Power Supply Replacement; Power Supply Replacement Overview; Identifying The Failed Power Supply - Nvidia DGX-2 System Service Manual

Hide thumbs Also See for DGX-2 System:
Table of Contents

Advertisement

Chapter 8.
This chapter describes how to replace one of the DGX-2 System power supplies (PSUs).
8.1. 

Power Supply Replacement Overview

This is a high-level overview of the steps needed to replace a power supply.
1. Identify failed power supply through the BMC and submit a service ticket.
2. Get replacement power supply from NVIDIA Enterprise Support.
3. Identify the power supply using the diagram as a reference and the indicator LEDs.
4. Remove the power cord from the power supply that will be replaced.
5. Remove the failed power supply.
6. Insert new power supply.
7. Insert the power cord and make sure both LEDs light up green (IN/OUT).
8. Use the BMC to confirm that the power supply is working correctly.
8.2. 

Identifying the Failed Power Supply

Identifying the Failed Power Supply from the Back
If physical access to the system is available, you can identify a failed PSU by the inspecting the
LEDs on the power supply.
Both LEDs should be solid green. If either of the LEDs are not green or if they are blinking,
contact NVIDIA Enterprise Support to troubleshoot the issue.
DGX-2 System
Power Supply Replacement
DU-09224-001 _v09   |   25

Hide quick links:

Advertisement

Table of Contents
loading