Advertisement

Quick Links

TeamWork
400 Kit • Installation Guide
®
TeamWork 400 Kit
The TeamWork 400 kit consists of an HDMI switcher, system controller, Cable Cubby
complete system that, in most cases, requires no configuration.
Extron
SW4 HD 4K
4K HDMI Switcher
Extron
Cable Cubby 1202
Furniture Mountable
Cable Access Enclosure
Extron Show Me Cables
The diagram above shows a typical TeamWork 400 application. The input devices (laptops and a tablet) connect to the switcher,
using Show Me
®
cables. The Show Me cables allow the user to select the active input on the switcher.
A control cable connects the RS-232 ports on the switcher and the system controller.
The system controller powers the display on and off. The system controller has been configured so that when a video signal is
detected on any of the switcher inputs, the display is powered on. A 30 second timer is started when no signal is detected on
any of the switcher inputs. If an active source is detected before the timer expires, the display remains on and the timer is reset. If
30 seconds pass without an active signal, the system controller powers off the display.
The TeamWork kits work, as described, without further software configuration. If you need to change the behavior or operation of
the system, you must configure the system controller (see the IPCP Pro Series User Guide at www.extron.com).
Contact Closure
& Tally
RS-232
Control Cable
+V
TO
T
A U
U T
G
-2 32
C
3
Y O
U T
LL
R S
T
/T A
T P
G
O U
C
1
C T
IN
4
N TA
G
C O
R x
2
Tx
T
G
C
T
Extron
G
C
T S
T S
4
HDMI Pro Cable
P U
P U
IN
IN
3
HDMI Video
2
4 K
D
4 H
1
S W
W E
R
P O
V
M A
X
12
0. 2A
, and cables packaged together as a
®
Extron
IPCP Pro PCS1
IP Link Pro
US
S1
PC
O
®
17T
T
PR
TED
EO
IP CP
LIS
VID
IO/
US
Power and Device
AUD
APA
RAT
L I/O
M
TA
CO
DI
GI
N
LA
M
V
CO
G
+5
Control Processor
3
2
RX
T
1
TX
PU
US
IR
O UT
G
eB
T
Rx
IN PU
G
z
AX
Tx
-S
N
/6 0H
A M
/S
+S
LA
~ 10
IR
+V
T
50
0V
G
PU
0- 24
6W
S
0- 12
IN
0V
10
T =
R OU
10
A M
AX
PW
IN
~ 10
0- 24
0V
G
S
A M
AX
10
U T
12
z
-6 0H
O U
TP
50
W ER
PO
z
-6 0H
AX
50
A M
12
Adapter
Flat Panel
AC Cord
Flat Panel
Display w/ Integrated
Speakers
1

Advertisement

Table of Contents
loading

Summary of Contents for Extron electronics TeamWork 400

  • Page 1 Furniture Mountable Cable Access Enclosure Extron Show Me Cables The diagram above shows a typical TeamWork 400 application. The input devices (laptops and a tablet) connect to the switcher, using Show Me ® cables. The Show Me cables allow the user to select the active input on the switcher.
  • Page 2: Kit Components

    TeamWork 400 Kit • Installation Guide (Continued) Features Standard systems support groups of up to four users. • Standard systems contain a complete turnkey package that includes cables, switcher, system controller, and Cable Cubby • enclosure. System controller pre-loaded with Global Configurator that requires no further adjustment.
  • Page 3: Display Requirements

    Display Requirements The TeamWork system is designed to work with most brands and models of flat panel displays available worldwide. For optimum performance, consider the following when selecting the displays for your TeamWork installation. The display should be tested thoroughly prior to installation or mass deployment of TeamWork systems. Power attributes —...
  • Page 4: Installation

    TeamWork 400 Kit • Installation Guide (Continued) Installation Install the Cable Pass-through Cassette Module and Show Me Cables Detailed instructions are in the Cable Cubby Setup Guide. Extron recommends the layout shown to the right with cable pass-through module to the left of the power module.
  • Page 5: Mounting And Placement Of System Components

    Mounting and Placement of System Components Decide where to install your TeamWork system and where to place the individual components. The Cable Cubby should provide easy access for as many users as possible. Ensure that there is ample space for cables •...
  • Page 6 TeamWork 400 Kit • Installation Guide (Continued) Cabling Extron IPCP Pro PCS1 IP Link Pro ® IP CP Power and Device L I/O Control Processor O UT IN PU /6 0H ~ 10 0- 24 0- 12 R OU ~ 10...
  • Page 7 HDMI Show Me Cables The Extron Show Me cables are for use with Extron TeamWork systems. They feature a Share button for remote input source selection and a control pigtail, which may be wired directly into Extron switchers with contact closure and tally outputs. HDMI Show Me cable INPUT OUTPUT...
  • Page 8: Connect The System Controller To The Switcher

    The system controller uses an internal power supply. Connect the power cord to a wall outlet. POWER 0.2A MAX The TeamWork 400 systems use a 4 input switcher with a 12 VDC, 1 A power supply, which is provided with the switcher. ATTENTION: Do not connect the power supply to the SW4 HD 4K switcher until you have read the Attention notifications in •...
  • Page 9: Testing The System

    Testing the System The TeamWork system has been pre-configured so that, once all the connections have been made and the devices are all powered on, there should be no need of further configuration for the system to work. To ensure that the system has been set up correctly, follow these steps: Power on the equipment: Source devices...
  • Page 10: Show Me Button Leds Stay Off When Pressed

    TeamWork 400 Kit • Installation Guide (Continued) Show Me Button LEDs Stay Off When Pressed: Cause 1 — The cable is not plugged into a source device that is producing an active video output signal: Solution — Verify that the source device is on and producing an active signal.