Installation; Preparation; Step 1-1 Choosing The Installation Location - Samsung AC TNXDKG Series Installation Manual

Hide thumbs Also See for AC TNXDKG Series:
Table of Contents

Advertisement

Preparation

Step 1-1 Choosing the installation
location
Installation location requirements
There must be no obstacles near the air inlet and
outlet.
Install the indoor unit on a ceiling that can support its
weight.
Maintain sufficient clearance around the indoor unit.
Before installing the indoor unit, be sure to check
whether the chosen location is well-drained.
WARNING
If appliances contain R-32 refrigerant, then the floor
area of the room in which the appliances are installed,
operated and stored must be larger than the minimum
floor area defined in table below A (m²).
Minimum required room area (A, m²)
m (kg)
≤ 1.842
1.843
1.9
2.0
2.2
2.4
2.6
2.8
3.0
3.2
3.4
3.6
3.8
4.0
4.2
4.4
4.6
4.8
5.0
m : Total refrigerant charge in the system
A : Minimum required room area
6 English
DB68-08947A-00_IM_CAC QMD_EU_EN_.indd 6
Do not install the air conditioner in following places.
Wall-mounted type
No requirement
4.45
4.58
4.83
5.31
5.79
6.39
7.41
8.51
9.68
10.9
12.3
13.7
15.1
16.7
18.3
20.0
21.8
23.6
IMPORTANT: it's mandatory to consider either the table
1 or taking into consideration the local law regarding
the minimum living space of the premises.
Minimum installation height of indoor unit is 0.6 m for
floor mounted, 1.8 m for wall, 2.2 m for ceiling.
CAUTION
The place where there is mineral oil or arsenic acid.
Resin parts flame and the accessories may drop or
water may leak. The capacity of the heat exchanger may
reduce or the air conditioner may be out of order.
The place where corrosive gas such as sulfurous
acid gas generates from the vent pipe or air outlet.
The copper pipe or connection pipe may corrode and
refrigerant may leak.
The place where there is a machine that generates
electromagnetic waves. The air conditioner may not
operate normally due to control system.
The place where there is a danger of existing
combustible gas, carbon fiber or flammable dust.
The place where thinner or gasoline is handled. Gas
may leak and it may cause fire.
The place where animals may urinate on the product.
Ammonia may be generated.
The place where is close to heat sources.
2020-02-10 오전 11:14:27