6
Apply heat to the contraction tube to contract it.
Method 1
Contraction tube
7
After tube contraction work is completed, wrap it with the
insulation tape to finish.
Three or more layers of insulation are required.
Method 1
Insulation tape
CAUTION
•
Make sure that the connection parts are not exposed
to outside.
•
Be sure to use insulation tape and a contraction tube
made of approved reinforced insulating materials
that have the same level of withstand voltage with
the power cable. (Comply with the local regulations on
extensions.)
WARNING
•
In case of extending the electric wire, please DO NOT use
a round-shaped Pressing socket.
‐
Incomplete wire connections can cause electric
shock or a fire.
DB68-08947A-00_IM_CAC QMD_EU_EN_.indd 13
Step 2-6 Connecting the drain hose
1
Method 2
Contraction tube
Method 2
Insulation tape
•
2
3
In Step 2-2, step 3 you determined the exit position for the
piping bundle. If using the right, bottom, or right rear exit,
change the drain hose connection from the right to the
left so that the drain hose will lie along the inside of the
unit and exit to the right.
Drain pan outlet
Rubber cap
CAUTION
Be careful not to puncture the plug with the
screwdriver when installing it.
If using the left, right, or bottom exit, pass the drain hose
through the selected knockout.
Drain hose
Refrigerant pipes
Connection hose
(assembly pipe)
Connect a 15.88 mm ID extension drain hose to the main
drain hose.
English
13
2020-02-10 오전 11:14:29