Heat Load, Charge And Condenser Gpm - Scotsman Prodigy Plus A Series Service Manual

Modular flake and nugget
Hide thumbs Also See for Prodigy Plus A Series:
Table of Contents

Advertisement

NH0422, NS0422, FS0522, NH0622, NS0622, FS0822, NH0922, NS0922, FS1222, NH1322, NS1322, FS1522
Air, Water or Remote Service Manual

Heat Load, Charge and Condenser GPM

Heat Load - Average heat load for air conditioning
unit sizing
Model
NH0422, NS0422, FS0522
NH0622, NS0622, FS0822
NH0922, NS0922, FS1222
NH1322, NS1322, FS1522
Water Cooled Water Use - Condenser Only
Model
GPM @ Supply
Water Temp
NH0422,
.14 @ 50
NS0422,
FS0522
NH0622,
.21 @ 50
NS0622,
FS0822
NH0922,
.68 @ 50
NS0922,
FS1222
NH1322,
.32 @ 50
NS1322,
FS1522
BTUH
5000
7100
10500
16000
GPM @ test
ambient
F water .23 @ 70
F water
o
o
F water .40 @ 70
F water
o
o
F water .76 @ 70
F water
o
o
F water .59 @ 70
F water
o
o
Refrigerant Charge
Model
NH0422A, NS0422A, FS0522A
NH0422W, NS0422W, FS0522W
NH0622A, NS0622A, FS0822A
NH0622W, NS0622W, FS0822W
NH0622R, NS0622R, FS0822R
NH0922A, NS0922A, FS1222A
NH0922W, NS0922W, FS1222W
NH0922R, NS0922R, FS1222R
NH0922A, NS0922A, FS1222A (-32)
NH0922W, NS0922W, FS1222W (-32) 28
NH0922A, NS0922A, FS1222A (-3)
NH0922W, NS0922W, FS1222W (-3)
NH1322A, NS1322A, FS1522A
NH1322W, NS1322W, FS1522W
NH1322R, NS1322R, FS1522R
July 2020
Page 32
R-404A (oz)
14
14
14
11
192
22
28
192
22
22
28
34
28
192

Hide quick links: