23 Troubleshooting Guide
Always remove the battery before carrying out any inspection, cleaning or maintenance.
Condition
LEDs on
Battery
Blower cuts out
1 LED glows
during operation.
red.
3 LEDs glow
red.
Run-time is too short.
Battery is not being
1 LED glows
charged even though
red.
LED on charger
glows green.
0458-824-8621-B
Cause
Remedy
Battery too hot / too
► Remove the battery, @ 14.2.
cold.
► Allow the blower and battery to cool down gradually at
Blower too hot.
ambient temperatures of about 50 °F to 68 °F (10 °C to
20 °C).
Battery not fully
► Charge the battery, @ 10.
charged.
Useful life of battery
► Have the battery checked by an authorized STIHL servicing
has been reached or
dealer.
exceeded.
Battery too hot / too
► Allow the battery to warm up or cool down gradually at
cold.
ambient temperatures of about 50 °F to 68 °F (10 °C to
20 °C).
► Operate the charger only in enclosed, dry rooms at ambient
temperatures of 41 °F to 104 °F (5 °C to 40 °C).