Operation; Controls - Vulcan-Hart VEX Installation & Operation Manual

Electric heavy duty ranges
Table of Contents

Advertisement

OPERATION

WARNING: THE RANGE AND ITS PARTS ARE HOT. USE CARE WHEN OPERATING, SERVICING AND
CLEANING THE RANGE.
WARNING (CONVECTION OVEN MODELS ONLY): WHEN USING CONVECTION OVENS, DO NOT STAND
DIRECTLY IN FRONT OF OVEN WHILE OPENING DOOR. ALTHOUGH OPENING OVEN DOOR WILL
AUTOMATICALLY SHUT OFF THE FAN, SOME HEAT ESCAPES. STEP AWAY TO AVOID HOT AIR.

CONTROLS

Top Surface Elements
CAUTION: Do not continuously operate surface units at maximum temperature; maximum temperature
operation will be required only during peak cooking intervals. Reduce heat during slow cooking periods
to save energy and prolong the life of the heating elements and castings.
Element Switches — control and maintain heat to surface elements.
Element Indicator Lights — when lit, indicates power is being supplied to the element.
There are 3 different types of plates that may be used in the VR, VS, VRC, VM, VEX and VMX Ranges.
PLATE & SIZE
Hot Top
12" X 24"
(305 x 610)
All Purpose Top
12" X 24"
(305 x 610)
with/without
trough
9
/
" (241) Dia.
1
2
French
Hot Plates
(or Optional
Hi-Speed
Elements)
Griddle Top 36"
(914)
Griddle Top 24"
(610)
*The 9
/
" (241) dia. French plates have separate thermostats built into each energy saving plate. With the
1
2
thermostat dial set at the highest available temperature and pan or pot containing food placed on the plate, the
plate will deliver 2,000 watts at a temperature lower than 800°F (427). When the cooking utensil is removed or
its contents have boiled dry, the heating watts are lowered as the temperature rises. Example: When the plate
reaches from 820°F to 850°F (438-455), wattage is cut back to 950 watts, a 52.5% reduction.
USED IN
MODELS
VR1,VR3,VM1,
VM3,VMT1,VMT3,
VEX1,VEX3,VMX1,
VMX3,VR1C,VR3C,
VS1,VS3
VR2,VR6,VM2,
VM6,VTM2,VTM6,
VEX2,VEX6,VMX2,
VMX6,VR2C,VR6C,
VS2, VS6
VR3,VR4,VR6,VR7
VM3,VM4,VM6
VTM3,VTM4,VTM6,
VEX3,VEX4,VEX6
VR3C,VR4C,VR6C,
VS3,VS4,VS6
VR5,VM5,VS5,
VR5C
VR7,VM7,VS7,
VR7C
CONTROLS
3-heat switch provides control of a single
element rated at 5 KW.
Thermostat provides control of a single
element rated at 5 KW. Indicator light
(next to thermostat) is ON when thermostat
calls for heat and goes OFF when
desired temperatire is reached.
Infinite switch (3-heat switch in 480 V.
models) provides (according to its setting)
a varying percent (about 7-100%) of its total
input to the elements. Rated at 2 KW.
(3) thermostats control heat to (3) individual 175-550°F
elements rated at 5 KW each. Each thermo- (79-288)
stat has its own indicator cycling light.
(2) thermostats control heat to (2) individual 175-550°F
elements rated at 5 KW each. Each thermo- (79-288)
stat has its own indicator cycling light.
(2) infinite switches rated at 2 KW each.
TEMP.
RANGE
340 to 800°F
(171 to 427)
340 to 800°F
(171 to 427)
*
*
11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

VmVmxVrVrcVs

Table of Contents