1. Plastic clip (2)
2. Secure the bottom of the fuel tank to the fuel tank
bracket by installing the self-tapping screws from the
bottom. Torque the screws to 40 to 50 in-lb (4.5
to 5.6 N-m).
4
Installing the Discharge Tunnel
Plug
Parts needed for this procedure:
1
Discharge tunnel plug
Procedure
1. Open the discharge door by pulling forward on the
handle and moving it rearward (Figure 6). Hold the
discharge door handle to prevent the spring-loaded
door from closing while you insert the plug.
Figure 5
1. Discharge-door handle
2. Since the plug is slightly wider than the discharge
tunnel opening, rotate the plug clockwise slightly while
inserting it (Figure 6).
Note: Ensure that the arrow on the plug decal points
upward.
3. Push the plug all the way in until the spring clip on the
bottom of the plug clicks into place, locking the plug
securely into the discharge tunnel (Figure 7).
1. Spring clip
4. Release the discharge-door handle to lock the top of
the plug.
5

Filling the Crankcase with Oil

No Parts Required
Procedure
Important: The engine crankcase is shipped without
oil. Before starting the engine, fill the engine with oil.
1. Move the machine to a level surface.
6
Figure 6
2. Plug, rotated clockwise