Trane Odyssey TWE0604*A/B Installation, Operation And Maintenance Manual page 20

Split system air conditioners odyssey with symbio controls air handler 5 to 25 tons
Table of Contents

Advertisement

D D i i m m e e n n s s i i o o n n a a l l D D a a t t a a
Figure 13. 16.7, 20.9, 20, 25 ton air handler, dual circuit
N N o o t t e e : : Duct flange is a field-installed accessory.
31 1/8"
(790.6)
DUCT FLANGE
16 5/16"
1" (25.4)
(414.3)
HEIGHT
18 7/8"
(479.4)
SUPPLY
OPEN
54 15/16"
(1395.4)
HEATER CONTROL
AND SINGLE POWER
ENTRY WIRES
6 7/16" (163.5)
31 1/8"
LINE VOLTAGE
(790.6)
CONTROL WIRING
CONTROL BOX
ACCESS PANEL
DRAIN CONNECTION
FOR HORIZONTAL
(SEE NOTE 2,3,5)
1 3/16"
28 1/2"
(30.2)
(724)
FILTER ACCESS PANEL
32" (813) MIN. DISTANCE
BOTH SIDE
LIQUID LINES
SEE NOTES 2,3,4
1 11/16"
(42.9)
9 5/8"
(244.5)
50 13/16"
71 7/8"
(1290.6)
(1825.6)
11 7/16"
(290.5)
20
NOTES:
1. PANEL DEPTH 1/2" (12.7) (TYP. ALL PANELS).
2. REMOVABLE DRAIN PAN AND ATTACHED DRAIN CONNECTION MAY BE INSTALLED ON END
4 15/16" (125.4)
OF UNIT IN EITHER THE VERTICAL OR HORIZONTAL CONFIGURATION, PLASTIC DRAIN PAN
ACCESS PLATE ON THE END OF UNIT OPPOSITE DRAIN CONNECTION MUST BE REMOVED TO
SLIDE DRAIN PAN OUT OF UNIT CLEANING. ACCESS PLATE MUST BE RE-INSTALLED AFTER
SLIDING DRAIN PAN BACK INTO UNIT.
3. IF PERIODIC DRAIN PAN CLEANING IS REQUIRED, ALLOW ROOM FOR PARTIAL REMOVAL OF
DRAIN PAN CONNECTION AT END OF UNIT.
4. 1" (25.4) FEMALE SCHED .40 (10.2) PVC PIPE DRAIN CONNECTION VERTICAL CONFIGURATION.
5. 1" (25.4) FEMALE SCHED .40 (10.2) PVC PIPE DRAIN CONNECTION HORIZONTAL CONFIGURATION.
92 9/16"
(2351.1)
20 15/16"
SIDE RETURN
(531.8)
18 5/8"
(473.1)
3"
(76.2)
4 3/4"
(120.6)
4 1/4" (108)
31 7/16" (798.6)
25 1/4"
(640.6)
REMOTE BULB TXV
SUCTION LINE
19 1/8"
18 3/8"
15 7/8"
12 7/8"
(485.8)
(466.7)
(403.2)
(327)
1 11/16" (42.9)
1 15/16" (49.2)
3 3/8" (85.7)
4" (101.6)
92 9/16"
(2351.1)
89 3/16"
(2265.4)
SIDE RETURN
BOTTOM RETURN
20 15/16"
SIDE RETURN
83 1/8"
(2111.4)
25 1/2"
21 3/8"
25 1/2"
21 13/16"
(647.7)
(542.9)
(647.7)
(554)
(4) - HOLE FOR HORIZONTAL
SUSPENSION
SUPPLY OPENING
SUPPLY VERTICAL -
RETURN HORIZONTAL /
RETURN VERTICAL
BOTTOM RETURN
(531.8)
2 15/16"
(74.6)
4 3/4"
83 1/8"
(120.6)
(2111.4)
COPPER LIQUID LINE
FIELD CONNECTION
COPPER SUCTION LINE
FIELD CONNECTION
21 13/16"
18 3/8"
19 1/8"
15 7/8"
(554)
(466.7)
(485.8)
(403.2)
1 9/16" (39.7)
1 7/8" (47.6)
3 1/4" (82.5)
3 7/8" (98.4)
(4) HOLE FOR
HORIZONTAL
SUSPENSION
SIDE RETURN
FILTER
BOTTOM RETURN
SUPPLY HORIZONTAL -
RETURN VERTICAL /
RETURN HORIZONTAL
BOTTOM RETURN
SEE NOTES
2,3,4
SSA-SVX06H-EN

Hide quick links:

Advertisement

Table of Contents
loading