Trane Odyssey TWE0604*A/B Installation, Operation And Maintenance Manual page 19

Split system air conditioners odyssey with symbio controls air handler 5 to 25 tons
Table of Contents

Advertisement

Figure 12. 10.4, 13, 12.5, 15 ton air handler, dual circuit
N N o o t t e e : : Duct flange is a field-installed accessory.
29 1/16"
DUCT FLANGE
(738.2)
1" (25.4)
16 5/16"
HEIGHT
(414.3)
12 3/8" (314.3)
SUPPLY
OPEN
54 15/16"
(1395.4)
SUPPLY
OPEN
HEATER CONTROL
AND SINGLE POWER
ENTRY WIRES
29 1/16"
(738.2)
LINE VOLTAGE
CONTROL WIRING
CONTROL BOX
ACCESS PANEL
DRAIN CONNECTION
FOR HORIZONTAL
(SEE NOTE 2,3,5)
1 1/4"
(31.8)
25 1/8"
(638.2)
FILTER ACCESS PANEL
32" (813) MIN.
DISTANCE
BOTH SIDE
LIQUID LINES
SEE NOTES 2,3,4
1 3/16"
(30.2)
9 5/8"
(244.5)
69 1/16"
48"
(1754.2)
(1219.2)
11 7/16" (290.5)
SSA-SVX06H-EN
NOTES:
1. PANEL DEPTH 1/2" (12.7) (TYP. ALL PANELS).
2. REMOVABLE DRAIN PAN AND ATTACHED DRAIN CONNECTION MAY BE INSTALLED ON END
OF UNIT IN EITHER THE VERTICAL OR HORIZONTAL CONFIGURATION, PLASTIC DRAIN PAN
ACCESS PLATE ON THE END OF UNIT OPPOSITE DRAIN CONNECTION MUST BE REMOVED TO
2 7/8" (73)
SLIDE DRAIN PAN OUT OF UNIT FOR CLEANING. ACCESS PLATE MUST BE RE-INSTALLED AFTER SLIDING
DRAIN PAN BACK INTO UNIT.
3. IF PERIODIC DRAIN PAN CLEANING IS REQUIRED, ALLOW ROOM FOR PARTIAL REMOVAL OF
DRAIN PAN CONNECTION AT END OF UNIT.
4. 1" (25.4) FEMALE SCHED. 40 (10.2) PVC PIPE DRAIN CONNECTION VERTICAL CONFIGURATION.
5. 1" (25.4) FEMALE SCHED. 40 (10.2) PVC PIPE DRAIN CONNECTION HORIZONTAL CONFIGURATION.
79 9/16"
(2020.9)
17 7/8"
SIDE RETURN
(454)
12 1/8"
3 5/16" (84.1)
(308)
2 3/4"
(69.8)
4 5/16" (109.5)
4 1/4" (108)
23 5/8" (600.6)
30 1/16"
(763.7
)
(2) REMOTE BULB TXV
SUCTION LINE
18 11/16"
18 5/16"
15 13/16"
(465.1)
(474.7)
12" (304.8)
(401.6)
1 5/16" (33.3)
2 1/8" (54)
2 7/16" (62)
4 1/4" (108)
79 5/8"
(2022.5)
77 3/16"
(1960.6)
SIDE RETURN
SIDE RETURN
3 7/16" (87.3)
74 1/8"
(1882.8)
22"
21 1/2"
21 1/2"
(558.8)
(546.1)
(546.1)
(4) - HOLE FOR HORIZONTAL
SUSPENSION
SUPPLY OPENING
BOTTOM RETURN
SUPPLY VERTICAL -
RETURN HORIZONTAL /
RETURN VERTICAL
D D i i m m e e n n s s i i o o n n a a l l D D a a t t a a
19 1/2"
(495.3)
BOTTOM RETURN
BOTTOM RETURN
2 3/4"
74 1/8"
(69.8)
(1882.8)
COPPER LIQUID LINE
FIELD CONNECTION
COPPER SUCTION LINE
FIELD CONNECTION
18 11/16"
18 3/8"
15 13/16"
(474.6)
(466.7)
(401.64)
2" (50.8)
2 5/16" (58.7)
4 1/8" (104.8)
(4) HOLE FOR
HORIZONTAL
SUSPENSION
BOTTOM RETURN
FILTER
SIDE RETURN
SUPPLY HORIZONTAL -
RETURN VERTICAL /
RETURN HORIZONTAL
SEE NOTES
2,3,4
19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents