D D i i m m e e n n s s i i o o n n a a l l D D a a t t a a
Figure 11. 8.33, 10 ton air handler, dual circuit
N N o o t t e e : : Duct flange is a field-installed accessory.
DUCT FLANGE
1" (25.4)
HEIGHT
19 11/16"
(500.1)
24 1/16"
(611.2)
HEATER CONTROL
AND SINGLE POWER
ENTRY WIRES
HEATER
VENTILATION
6 13/16" (173)
LINE VOLTAGE
CONTROL WIRING
CONTROL BOX
ACCESS PANEL
DRAIN CONNECTION
FOR HORIZONTAL
(SEE NOTE 2,3,5)
1 3/16"
22 7/8"
(30.2)
(581)
FILTER ACCESS PANEL
22" (558.8) MIN. DISTANCE
BOTH SIDE
LIQUID LINES
SEE NOTES 2,3,4
1 3/16"
(30.2)
6 3/4"
(171.45)
36 7/8"
54 1/16"
(936.6)
(1373.2)
10 7/16" (265.1)
18
NOTES:
1. PANEL DEPTH 1/2" (12.7) (TYP. ALL PANELS).
2. REMOVABLE DRAIN PAN AND ATTACHED DRAIN CONNECTION MAY BE INSTALLED ON END
25 1/2"
(647.7)
0.70" (17.8)
16 1/4"
(412.7)
3. IF PERIODIC DRAIN PAN CLEANING IS REQUIRED, ALLOW ROOM FOR PARTIAL REMOVAL OF
4. 1" (25.4) FEMALE SCHED. 40 (10.2) PVC PIPE DRAIN CONNECTION VERTICAL CONFIGURATION.
5. 1" (25.4) FEMALE SCHED. 40 (10.2) PVC PIPE DRAIN CONNECTION HORIZONTAL CONFIGURATION.
63 1/2"
SUPPLY
(1613)
OPEN
15 15/16"
(404.8)
20 5/16"
16 5/16"
(515.9)
1 11/16"
(414.3)
2 1/4" (57.15)
25 1/2"
(647.7)
3 1/2" (89.4)
10 9/16"
(268.5) 16 9/16"
(420.9)
(2) REMOTE BULB TXV
SUCTION LINE
16 1/4"
13 11/16"
(412.8)
11" (279.4)
(347.7)
1 5/16" (33.4)
1 5/8" (41.3)
3 5/8" (92.1)
61 1/8"
(1552.6)
OF UNIT IN EITHER THE VERTICAL OR HORIZONTAL CONFIGURATION, PLASTIC DRAIN PAN
ACCESS PLATE ON THE END OF UNIT OPPOSITE DRAIN CONNECTION MUST BE REMOVED TO
SLIDE DRAIN PAN OUT OF UNIT FOR CLEANING. ACCESS PLATE MUST BE RE-INSTALLED AFTER
SLIDING DRAIN PAN BACK INTO UNIT.
DRAIN PAN CONNECTION AT END OF UNIT.
SIDE RETURN
(42.9)
2 3/4"
58"
(69.8)
(1473.2)
20"
19"
16 11/16"
(508)
(482.6)
(423.9)
(4) - HOLE FOR HORIZONTAL
SUSPENSION
SIDE RETURN
BOTTOM RETURN
SUPPLY VERTICAL -
RETURN HORIZONTAL /
RETURN VERTICAL
16 7/8"
BOTTOM RETURN
(428.6)
1 13/16"
(46)
2 3/4"
58"
(69.8)
(1473.2)
COPPER LIQUID LINE
FIELD CONNECTION
COPPER SUCTION LINE
FIELD CONNECTION
20 1/16"
16 3/4"
16 1/4"
13 3/4"
(509.6)
(425.5)
(412.8)
(349.3)
1 5/16" (33.3)
1 5/8" (41.3)
3 5/8" (92.1)
(4) HOLE FOR
HORIZONTAL
SUSPENSION
SUPPLY OPENING
BOTTOM RETURN
FILTER
SIDE RETURN
SUPPLY HORIZONTAL -
RETURN VERTICAL /
RETURN HORIZONTAL
SSA-SVX06H-EN
SEE NOTES
2,3,4