Repair

Replacing flowmeter

Tools:
-
Torx screwdriver T10
-
Long-nose pliers
-
Pot to collect water
Procedure:
1 Follow general disassembly stage 1 and 2
(see pages 24 and 25).
2 Unplug connector from flowmeter (63).
3 Remove hoses (55 and 58) from
flowmeter (63). Collect outflowing water in
pot.
4 Slide carrier (29) out of base plate (1).
5 Remove fixing clip (28) and replace
defective flowmeter (63).
6 Assemble in reverse sequence.
Check hose connection after
assembly!
to pump
31
to water tank
connector