HP Smart Array -UX 11i v2 Support Manual page 115

Sas controllers for integrity servers
Hide thumbs Also See for Smart Array HP-UX 11i v2:
Table of Contents

Advertisement

Table 20 Smart Array controller POST error codes (continued)
Error
code
1795
Slot z Drive Array - Array Accelerator
Configuration Error. Data does not correspond to
this drive array
Array Accelerator is temporarily disabled.
1796
Slot z Drive Array - Array Accelerator is Not
Responding.
Array Accelerator is temporarily disabled.
1797
Slot z Drive Array - Array Accelerator Read Error
Occurred.
Data in Array Accelerator has been lost.
Array Accelerator is disabled.
1798
Slot z Drive Array - Array Accelerator Self-Test
Error Occurred.
Array Accelerator is disabled.
1799
Slot z Drive Array - Drive(s) Disabled due to Array
Accelerator Data Loss.
1799
179A-Slot z Drive Array – Array Accelerator is
disabled Unknown Problem Code).
Array accelerator is temporarily (permanently )
disabled.
Description
Level
Critical
Check the array configuration.
Critical
Check the cache module, and replace
if necessary.
Critical
The cache module has failed. Contact
your HP service representative for
assistance.
Critical
The cache module has failed. Contact
your HP service representative for
assistance.
Critical
Press F1 to continue with logical drives
disabled. See
Press F2 to accept data loss and
re-enable logical drives.
Warning: Pressing F2 erases all data
in the array. Be sure you have a valid,
current backup of the affected logical
drives before selecting this option.
Critical
The cache module has failed. Contact
your HP service representative for
assistance.
Corrective action
Chapter 4 (page
59).
POST error codes
1 15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smart array hp-ux 11i v3

Table of Contents