Loading firmware from a bank other than the default bank during startup
Procedure
1. Press and hold the reset button.
2. Press and hold the ASB button.
3. Release the reset button.
4. Release the ASB button.

The front panel of the Avaya MM710B media module

The MM710B T1/E1 media module terminates a T1 or E1 trunk facility. For T1 connections, you
can provision the MM710B to either utilize the integrated Channel Service Unit (CSU) capabilities
or connect directly to an external CSU
Note:
This information also applies to the MM710.
Note:
For drop and insert, an external CSU is required.
Figure 33: The MM710B media module front panel
Note:
The six ports in the middle of the front panel are used for testing.
MM710B ports
The MM710B contains an E1/T1 port.
MM710B LEDs
Table 14: MM710B LEDs
LED
Name
ALM
Alarm
TST
Test
July 2018
Color
Indication
Red
The module type is not the type configured in the MSG for
the slot
Green
Either a test is being performed on the module via the
server, or the module is performing a self-test upon initial
insertion