WATER CONNECTION

Water Supply

•This ice machine must be connected to a potable, active cold water supply line delivering water pressure at a minimum
pressure of 20 psi and maximum of 120 psi.
•Water connection is made through a 1/4" (.64 cm) compression right angle garden hose fitting. D D o o n n o o t t u u s s e e a a n n y y t t h h r r e e a a d d
s s e e a a l l e e r r s s . . N N O O T T E E : : T T h h e e w w a a t t e e r r l l i i n n e e f f i i t t t t i i n n g g s s u u p p p p l l i i e e d d w w i i t t h h y y o o u u r r i i c c e e m m a a c c h h i i n n e e i i s s t t o o b b e e u u s s e e d d o o n n a a 1 1 / / 4 4 " " ( ( . . 6 6 4 4 c c m m ) ) c c o o p p p p e e r r w w a a t t e e r r s s u u p p p p l l y y
l l i i n n e e o o n n l l y y . . D D o o n n o o t t a a t t t t a a c c h h a a p p l l a a s s t t i i c c s s u u p p p p l l y y l l i i n n e e t t o o y y o o u u r r u u n n i i t t u u s s i i n n g g t t h h i i s s f f i i t t t t i i n n g g . .
Rubber washer
• • A A w w a a t t e e r r f f i i l l t t e e r r i i s s r r e e c c o o m m m m e e n n d d e e d d f f o o r r t t h h i i s s u u n n i i t t . . A quality filter can remove particles as well as remove taste and odors from water.
•Do not use a reverse osmosis water filtration system with the ice machine.
•S S o o f f t t e e n n e e d d w w a a t t e e r r i i s s n n o o t t r r e e c c o o m m m m e e n n d d e e d d . . This will produce mushy, cloudy ice cubes that will stick together.
•D D e e - - i i o o n n i i z z e e d d w w a a t t e e r r i i s s n n o o t t r r e e c c o o m m m m e e n n d d e e d d . This water will not form solid ice cubes.
•A water specialist can recommend proper water treatment.
•After installation of water line, turn on water and check for any leaks. Additional tightening may be needed. D D o o n n o o t t u u s s e e a a n n y y
t t y y p p e e o o f f t t h h r r e e a a d d s s e e a a l l e e r r . .
•Allow extra water line for easy removal of unit and to help prevent the water line from kinking.
5/8" (.63 cm) I.D. DRAIN
TUBING BARB
MAKE CERTAIN ALL HOSE
CLAMPS ARE SECURE
Adapter
Compression fitting
Compression nut
REAR OF UNIT
GARDEN HOSE
FITTING
5 1/2" (14.0 cm)
2 1/8" (5.4 cm)
COMPRESSION FITTING
Fitting valve
10
1/4" (.64 cm) TUBING FROM
COLD WATER LINE
1/4" (.64 cm) copper
water supply line
(supplied by customer)
From water supply
to ice machine