86
2-2. Charging
Safety functions
The CCID (Charging Circuit Interrupting Device) has the following
safety features.
Electrical leakage detection function
If an electrical leakage is detected during charging, the power
source will be automatically interrupted, thus preventing fires or
electrical shocks caused by electrical leakage.
If the power source is interrupted, the error warning indicator will illumi-
nate. If the power source is interrupted: P. 382
Electrical leakage test function
The electrical leakage detection function can be tested prior to
charging to confirm that it is operating correctly.
When the test button is pressed while the plug is connected to an exter-
nal power source, the error warning indicator should illuminate.
(P. 262)
Conditions for supplying current to the vehicle
The CCID (Charging Circuit Interrupting Device) is designed to pre-
vent electrical current from being supplied to the charging connec-
tor when it is not connected to the vehicle, even if the plug is
inserted in the outlet.