Installation

6.8 Finishing the outdoor unit installation

6.8.1 To finish the outdoor unit installation

Installer reference guide
50
a-A
a-C
e-A
a
Terminal for room (A, B, C, D, E)*
b
Circuit breaker
c
Earth leakage circuit breaker
d
Power supply wire
e
Interconnection wire for room (A, B, C, D, E)*
*May differ depending on the model.
5 Tighten the terminal screws securely using a Philips screwdriver.
6 Check that the wires do not disconnect by pulling them lightly.
7 Firmly secure the wire retainer to avoid external stress on wire terminations.
8 Pass the wiring through the cutout on the bottom of the protection plate.
9 Make sure the electrical wiring does not contact with the gas piping.
a
Wire retainer
10 Reattach the switch box cover and the service cover.
NOTICE
It is recommended that the refrigerant piping between indoor and outdoor unit is
installed in a ducting or the refrigerant piping is wrapped with finishing tape.
1 Insulate and fix the refrigerant piping and cables as follows:
a-B
a-D
b
a-E
e-D
e-C
e-B
e-E
L N
1 2 3
a
1 2 3
c
d
3(A)MXM+3(A)MXF+4MXM+5MXM
4P600463-1B – 2020.05