Installation

6.7 Connecting the electrical wiring

6.7.1 About connecting the electrical wiring

6.7.2 Precautions when connecting the electrical wiring

Installer reference guide
46
Typical workflow
Connecting the electrical wiring typically consists of the following stages:
1
Making sure the power supply system complies with the electrical
specifications of the heat pump.
2
Connecting the electrical wiring to the outdoor unit.
3
Connecting the electrical wiring to the indoor unit.
4
Connecting the main power supply of the indoor unit.
5
Connecting the main power supply of the gas boiler.
6
Connecting the communication cable between the gas boiler and the indoor
unit.
7
Connecting the user interface.
8
Connecting the shut-off valves.
9
Connecting the domestic hot water pump.
10
Connecting the alarm output.
11
Connecting the space heating ON/OFF output.
12
Connecting the safety thermostat.
INFORMATION
Also read the precautions and requirements in the following chapters:
General safety precautions
Preparation
WARNING
Appliance shall be installed in accordance with national wiring regulations.
DANGER: RISK OF ELECTROCUTION
WARNING
ALWAYS use multicore cable for power supply cables.
WARNING
Use an all-pole disconnection type breaker with at least 3 mm between the contact
point gaps that provide full disconnection under overvoltage category III.
WARNING
If the supply cord is damaged, it MUST be replaced by the manufacturer, its service
agent or similarly qualified persons in order to avoid a hazard.
3(A)MXM+3(A)MXF+4MXM+5MXM
R32 Split series
4P600463-1B – 2020.05