3(A)MXM+3(A)MXF+4MXM+5MXM
R32 Split series
4P600463-1B – 2020.05
1
2
Reducer type
1
2
3
4
5
6
Connection examples:
▪
Connecting a Ø12.7 mm pipe to a Ø15.9 mm gas pipe connection port
a
b
a
Outdoor unit connection port
b
Reducer no. 1
c
Reducer no. 3
d
Flare nut for Ø15.9 mm
e
Inter-unit piping
▪
Connecting a Ø9.5 mm pipe to a Ø15.9 mm gas pipe connection port
a
b
a
Outdoor unit connection port
b
Reducer no. 6
c
Reducer no. 5
d
Flare nut for Ø9.5 mm
e
Inter-unit piping
▪
Connecting a Ø9.5 mm pipe to a Ø12.7 mm gas pipe connection port
a
b
a
Outdoor unit connection port
b
Reducer no. 2
c
Reducer no. 4
d
Flare nut for Ø12.7 mm
e
Inter-unit piping
Coat the threaded connection port of the outdoor unit where the flare nut comes
in with refrigeration oil.
Flare nut for (mm)
Ø9.5
Ø12.7
Ø15.9
3
4
5
Connection
Ø15.9 mm → Ø12.7 mm
Ø12.7 mm → Ø9.5 mm
Ø15.9 mm → Ø12.7 mm
Ø12.7 mm → Ø9.5 mm
Ø15.9 mm → Ø9.5 mm
Ø15.9 mm → Ø9.5 mm
c
d
c
d
c
d
Tightening torque (N•m)
6
Installation
|
6
e
e
e
33~39
50~60
62~75
Installer reference guide
37