(Eic) Electronic Instrument Cluster Front Panel - New Holland LS160 Manual

Hide thumbs Also See for LS160:
Table of Contents

Advertisement

(EIC) ELECTRONIC INSTRUMENT
CLUSTER FRONT PANEL
1. AUDIBLE ALARM
The audible alarm will sound if there is an
unusual condition in any of the monitored areas.
The audible alarm is located behind the front
panel at 1.
2. CHARACTER DISPLAY
The character display will display the item that
the operator has chosen to monitor. The display
shows one function at a time. After the engine is
started, the display defaults to the last function
viewed at power off. Any of the other functions
may be selected by the operator during operation
by briefly pressing the "ARROW" selector switch,
3. When the EIC is turned off and then powered
up, the display default will be the newly
selected function.
SECTION 55 - ELECTRICAL SYSTEM
3. RIGHT
4. OPEN BOOK SELECTOR SWITCH
55-20
ARROW
DISPLAY
SWITCH
The display selector switch, covered with an
"ARROW" symbol, will cause an audible "chirp"
when pressed if the ignition key is in the "RUN"
position. Pressing the "ARROW" symbol during
operation will select the function that the operator
chooses to monitor and will be displayed in the
character display, 2. If a sensor causes a warning
or fault, the appropriate lamp will flash,
accompanied by an audible alarm. Pressing this
switch also cancels any audible alarm that
is sounding.
This selector switch covered with the symbol of
an "OPEN BOOK" (instruction manual) is used to
select other functional modes of the EIC panel.
The "OPEN BOOK" switch has no function during
normal operation.