Technology > Pickup / Feed System > Overview > Specification

Pickup / Feed System

Overview

In pickup feed system, paper is fed from the pickup area to the delivery area.
This machine is equipped with the new technology "active registration" to realize the 135
sheet/min high-speed printing and high accuracy registration.
In addition, air pickup method is adopted that is the same pickup method with image PRESS
7000 series.
2
Technology > Pickup / Feed System > Overview > Specification
Active registration area
(Registration unit)
Deck area air pickup
F-2-111
■ Specification
Item
Paper storage
Pickup unit
Main body
*1
POD Deck
Side Paper Deck
(For outside Japan only)
*2
Pickup method
Main body
POD Deck
*1
Side Paper Deck
*2
(For outside Japan only)
Paper stackability Main body
*1
POD Deck
Side Paper Deck
*2
(For outside Japan only)
Maximum registration size
Maximum print area
Paper size
Paper grammage
Paper size switch
Pickup feed reference
Duplexing print method
Paper level display
Transparency detection
Double feed detection
Leading edge margin
Right margin
*1
One POD deck is installed as a standard to Finisher-AF series. It cannot be installed to
Finisher-AG series.
*2
Side Paper Deck is installed as a standard to Finisher-AG series. It cannot be installed
to Finisher-AF series.
Regarding the pickup/delivery option, see Chapter 1, "Pickup and delivery system options.".
2-82
Function/method
Front loading method
Deck x 1
Deck x 3
Deck x 3
Air separation method
Air separation method
Retard separation method
2000 sheet x 1 (80g/m
2
)
2
1000 sheet x 2, 2000 sheet x 1 (80g/m
)
2000 sheet x 3 (80g/m
2
)
330.2 x 487.7mm(13"x19.2")
320.6 x 482.7mm
A4, A4R, A3, B4, B5, B5R,
304.8X457.2mm, 320 x 450mm(SRA3),
330.2X482.6mm, 8K, LTR, LTRR, LGL,
11" x 17", 13" x 19.2"(330.2 x 487.7mm)
52g/m
2
to 300g/m
2
By input on the control panel by users
Center reference
Through path method
Yes (control panel/deck level LED)
Yes (transparent sensor)
Yes (ultrasound wave sensor)
2.5 ± 0.5mm
2.5 ± 0.5mm
2-82
T-2-79