LINER INSTALLATION - Fig. 6
The collar extending down from the termi-
nation base is the air intake connector. Be
sure the flex vent, which is connected to
this collar, is also connected to the labelled
air intake flue collar on the fireplace. Make
sure the Flex vent is attached on the correct
collar and cap for exhaust as well.
Slide the insulation provided in the termination kit over the
two (2) 3" flex liners, (to be attached to the 3" Flue collar
and cap of the termination). Feed one 3" flex vent from the
bottom of the termination up through the 4" sleeve. Apply
hi-temp sealant on the rain cap collar and slide the flex
vent over the end of the rain cap collar fastening with the
clamp provided. Slide the flex liner back down the 4"
sleeve until 4" cap slides over the sleeve. Attach cap to the
sleeve with four (4) screws supplied.
sealant over the air intake collar and attach intake flex vent
in the same method. Feed the two flex liners down the
chimney through the damper opening. Tighten termination
to the chimney using the screws provided.
In case the fireplace opening is only minimum height 21"
(533mm) and access from the front is not possible, then
follow the instructions below.
1. Remove flue collar plate assembly. Unbolt the top
fastener plate and move it to the back first before
sliding the flue collar plate out from the top of the unit.
(See Fig. 7)
2. Apply a bead of hi-temp sealant on the end of the
collar before attaching the liner to the flue collar.
Fasten it with two clamps then adjust fastener plate all
the way to the back before sliding flue gas plate back
onto the unit. (See Fig. 8 and Fig. 9).
3. After the flue collar plate is set on the cabinet top, make
sure the front edge of the flue collar plate is completely
in contact with the back edge of the cabinet top (See
Fig. 10).
4. Put the machine screw back into the fastener plate.
Bolt the plate until it is locked. (See Fig. 11).
Under no circumstances should
insulation be put between the damper
and the top of the unit. This may cause
condensation and overheating of the unit.
10003929
Outside combustion air
enters through the
lower level of the
vent termination
Secure with clamp
and three screws
Apply hi-temp
FLUE COLLAR PLATE

VENTING DIAGRAM

Flue gas exits
through the vent
termination rain cap
AIR INTAKE
AIR INTAKE COLLAR
WITH LABEL SECURED
WITH CLAMP AND
THREE SCREWS
AIR INTAKE
MOVE
BACK
FIG .1
1) Attach flexible pipe to rain cap
2) Secure with clamp
3) Attach raincap to vent
termination using three screws
Pull flexible pipe
through vent
termination
A or B vent with
7" 0 inside minimum
and 14" outside maximum
NOTE:
Minimum Vent Height - 12 feet
Maximum Vent Height - 35 feet
EXHAUST
EXHAUST COLLAR SECURED
WITH CLAMP AND THREE
SCREWS
Fig. 6
FASTENER PLATE
CABINET TOP
10/24"X 1 1/2" MACHINE SCREW
Fig. 7