Pre-Installation Checklist
Are you burning Natural Gas? If you have Propane Gas, you need to purchase a
factory authorized safety pilot kit (see below).
Is the gas supply inlet pressure correct? NG: Min. 3.5" w.c./Max. 7.0" w.c.
Does the firebox meet the minimum size dimensions below?
Is your fireplace plumbed with gas on the right side (facing) of the fireplace?
If not, see Page 4.
Is the gas supply line sized properly (Minimum 1/2" iron pipe)?
Do you have a solid fuel (wood burning) fireplace with a vented flue?
Do you have a manual gas supply valve installed at your fireplace? If not, a licensed
plumber, gas company technician or other qualified installer must install one.
Have you checked local building codes? (Check with your local building department)
Does your fireplace have a wire mesh screen in place?
CAUTION: If you answered "NO" to any item, or have any questions regarding your installation, please
contact your dealer/distributor for assistance.
Set
Input
Size
Btu/hr
18"
54,000
24"
90,000
30"
90,000
NOTE: Use of a Pilot or LP Conversion Kit will add 3" to the minimum width requirements.
Refer to the pilot kit's installation instructions.
USE OF THIS SET WITH LP OR PROPANE FUEL REQUIRES THE INSTALLATION OF ONE
OF OUR FACTORY AUTHORIZED SAFETY PILOT KITS:
MODEL SPK P - Pilot Kit with Piezo Spark Ignition
MODEL RVKRP - Millivolt Pilot Kit with Remote Control Capabilities
4
Minimum Clearances & Specifications
Natural Gas Units
Minimum Firebox Dimensions
Width
Back
Front
Depth
16"
24"
15"
20"
30"
15"
27"
36"
18"
Propane (LP) Conversion
Minimum
Flue
Height
Size
18"
51 sq.in.
18"
79 sq.in.
18"
79 sq.in.
Yes
No
Gas Fuel Line
Pressure
Minimum
Maximum
3.5" w.c.
7.0" w.c.
3.5" w.c.
7.0" w.c.
3.5" w.c.
7.0" w.c.