Screen Information; Electrical Connection; Service Instructions; Removal Of Logs - Vermont Castings DEF Installation And Operating Manual

Vermont castings electric fireplace homeowner's installation and operating manual def, defd26
Table of Contents

Advertisement

Vermont Castings, Majestic Products DEF/ DEFD26

Screen Information

1. Under no circumstances is this product to be
operated if the screen door(s) are missing.
2. Do not strike or slam the screen doors.
3. This product uses screen doors. Replacement
screen doors are available from the manufacturer.
Replacement must be carried out by a qualified
service person.

Electrical Connection

A 15 AMP, 120 Volt, 60 Hz circuit with a properly
grounded outlet is required. Preferably, the fireplace
will be on a dedicated circuit as other appliances on
the same circuit may cause the circuit breaker to trip or
the fuse to blow when the heater is in operation.
The unit comes standard with a 6' (1828 mm) long
3-wire cord, exiting from the side of the fireplace.
Plan the installation to avoid the use of an extension
cord. If an extension cord must be used, it must be a
minimum 14 AWG, 3-wire cord with grounding-type
plug connector, and rated not less than 1875 Watts.
The cord shall not be more than 20' (6.1 m) in length.

Removal of Logs

1. Turn OFF power to the unit by unplugging the
power cord.
2. Let fireplace cool if it has been operating.
3. Gently open both screen doors.
4. Remove the two (2) screws securing the ember bed
and logset in position. One (1) screw is located on
either side of the ember bed near the center.
Fig. 1 Electric logset
WARNING: Disconnect power before
attempting any maintenance or cleaning
to reduce the risk of fire, electrical shock
or personal injury.
6

Service Instructions

LG237_DEF26_logs
WARNING: Electrical outlet wiring must
comply with local building codes and
other applicable regulations to reduce
the risk of fire, electrical shock and
injury to persons.
WARNING: Do not use this fireplace if
any part of it has been under water.
Immediately contact a qualified service
technician to inspect the fireplace and
replace any part of the electrical system.
WARNING: This fireplace comes with a
manual circuit breaker reset near the
power cord supply. In case the fireplace
is not operating check the circuit breaker
and reset the button at the breaker. If the
fireplace remains inoperable,
immediately contact a qualified service
technician to perform an inspection.

Cleaning Trim

Clean the metal trim using a soft cloth, slightly
dampened with lemon oil, then buff with a clean soft
cloth. DO NOT use brass polish or household
cleaners, as these products will damage the metal
trim. Lemon oil may be obtained at supermarkets and
hardware stores.
10005581