Operation; Your First Fire; Pilot And Burner Inspection; Flame & Temperature Adjustment - Vermont Castings 4030 - 4049 Installation And Operating Manual

Vermont vent free gas heaters homeowner's installation and operating manual
Table of Contents

Advertisement

Your First Fire

Read these instructions carefully and familiarize
yourself with the burner controls shown on Page 17.
Locate the pilot assembly, Figure 22. Follow the lighting
instructions on Page 16 exactly.
During the first fire, it is not unusual to smell some
odor associated with new logs, paint and metal being
heated. Odors should dissipate within the first eight to
ten hours, however, you can open a window to provide
fresh air to alleviate the condition.

Pilot and Burner Inspection

Each time you light your heater check that the pilot
flame and burner flame patterns are as shown in Fig-
ures 25 and 26. If flame patterns are incorrect, turn the
heater off. Contact your dealer or a qualified gas techni-
cian for assistance. Do not operate the heater until the
pilot flame is correct.
Follow regular maintenance procedures as described
on Page 19.
ST673
Fig. 22 Pilot assembly location.
RUVSOD
Pilot assembly location
7/249/01 djt
Flame & Temperature Adjustment
RN/RP Models
For units equipped with 'HI/LO' valves the flame adjust-
ment is accomplished by rotating the 'HI/LO' adjustment
knob located near the center of the gas control valve.
(Figs. 23, 24)
20007068

Operation

Natural
Pilot
LP Pilot
ST673
Turn
counterclockwise
to decrease
flame height
Fig. 23 Flame adjustment knob for Honeywell Valve.
Turn
counterclockwise
to increase
flame height
Fig. 24 Flame adjustment knob for Eurosit Valve.

Flame Characteristics

It is important to periodically perform a visual check of
the pilot and burner flames. Compare them to the picto-
HV117
rial illustrated below. (Figs. 25, 26) If the flame patterns
Eurosit control
appear abnormal contact a qualified service provider for
knob
service and adjustment.
2/19/02 djt
Fig. 25 Correct pilot flame appearance.
Fig. 26 Correct burner flame pattern.
LG224
UVS27
logs in place
UVS27 Vent-Free Gas Heater
Turn clockwise
to increase
flame height
SIT 630
HV102
Turn clockwise
Honeywell hi/lo knob
to decrease
4/5/99 djt
flame height
ST198
pilot flame detail
11/99
HV102
HV117
ST198
LG225
15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Uvs27rUvs27m4085-40874090-4092

Table of Contents