12. Insert blue painted screw when converting to
natural gas and red painted screw when converting
to LP.
13. Tighten screw (do not over tighten), replace cap.
14. Locate pilot. (Fig. 38)
15. Replace pilot orifice.
Remove pilot hood by lifting up. (Fig. 41) NOTE: It
is not necessary to remove the pilot tube for conver-
sion.
Pilot Hood
Pilot
Bracket
Fig. 41 Remove pilot hood.
Remove pilot orifice with allen wrench. (Fig. 42)
Install the conversion orifice.
Reinstall pilot hood. Be sure to align hood with
index tab.
Index Tab
Snap Ring
CO106a
Fig. 42 Remove pilot orifice.
Kit #
000-5009
Kit #
000-5010
Minimum rear injector air inlet openings.
20
20
Allen Wrench
Table 2. Injector Orifice Size Matrix
Conversion to Natural Gas
Front
Part #
#51
30000449
Conversion to LP
Front
Part #
#57
20004587
Table 3. Air Shutter Adjustment
Model
RNVOD
16. Air shutter adjustment. The unit is shipped from the
factory with the air shutter open 1". For LP units only,
the air shutter could be closed further. Refer to Table
3 for minimum air shutter opening. The air shutter is
located on the bottom of the burner to the left. (Fig.
43)
17. Replace burner. Slide the burner in at an angle with
left side lower than the right side. Slide the left side
onto the injectors, making sure the burner leg
remains at a 90° angle to the base. Lower the right
hand side down in to place. Make sure the burner is
as far left as possible and the injector shoulders are
inside the burner.
NOTE: It is very critical to keep the left burner leg,
which holds the injectors, at a 90° angle to the base.
(Fig. 39) This keeps the orifices aligned with the
tubes inside burner. Failure to do so could affect the
flame appearance and performance of the unit.
CO105a
18. Place conversion label on valve.
19. Reinstall the right and left log bracket assembly.
20.Reinstall the rear log bracket.
21. Replace logs.
22.Replace glass and stove front.
Conversion is complete.
Refer to Table 2
Fig. 43 Adjust air shutter on bottom of heater, Refer to
Table 2 for correct position.
Rear
Part #
#40
20004263
Rear
Part #
#54
20000130
Natural Gas
Bottom of Burner Pan
Input (BTU/h)
Minimum
Maximum
25,000
35,000
Input (BTU/h)
Minimum
Maximum
27,500
35,000
LP
1 "
Fully Closed
ST667
20004409