Direct Vent Gas Stove
Installation and Operating Instructions
Models: CSDV30SNVGCSB, CSDV30SPVGSCB,
CSDV30NVEMBCSB, CSDV30PVEMBCSB
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death or
property damage.
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
– Do not try to light any appliance.
– Do not touch any electrical switch; do
not use any phone in your building.
– Leave the building immediately.
– Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
– If you cannot reach your gas supplier,
call the fire department.
Installation and service must be performed
by a qualified installer, service agency or
the gas supplier.
WARNING: Improper installation, adjustment,
alteration, service or maintenance can cause
injury or property damage. Refer to this manual.
For assistance or additional information consult
a qualified installer, service agency or the
gas supplier.
This appliance is for use only with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless
a certified kit is used.
This appliance may be installed in an aftermarket,*
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
* Aftermarket: Completion of sale, not for purpose of resale, from
the manufacturer.
DANGER
586056
CSDV cover
A barrier designed to reduce the risk of burns from the hot
viewing glass is provided with this appliance and shall
be installed for the protection of children and
other at risk individuals.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future
reference.
CERTIFIED
S
B
AFETY
ARRIER
ON
F
OF
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
20306543
20306757 12/14 Rev. 1

Advertisement

Table of Contents
loading

Summary of Contents for Vermont Castings CSDV30SNVGCSB

  • Page 1 Direct Vent Gas Stove Installation and Operating Instructions Models: CSDV30SNVGCSB, CSDV30SPVGSCB, CSDV30NVEMBCSB, CSDV30PVEMBCSB CERTIFIED AFETY ARRIER WARNING: FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death or property damage. • Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 2: Table Of Contents

    CONGRATULATIONS You have purchased a state-of-the-art gas appliance featuring the Lex-Fire Burn System available exclusively on Vermont Castings Group. The Lex-Fire Burn System sets a new standard for flame appearance through innovative log design, burner technology and ember placement. Each element affecting combustion and flame appearance was carefully scrutinized and strategically balanced during the design process.
  • Page 3: Important Safety Information

    IMPORTANT SAFETY INFORMATION CSDV Series Direct Vent Gas Stove INSTALLER OWNER Please leave these instructions with the appliance. Please retain these instructions for future reference. WARNING • Read this owner’s manual carefully and completely before trying to assemble, operate, or service this fireplace.
  • Page 4: Code Approval

    CODE APPROVAL CSDV Series Direct Vent Gas Stove 13. Never place anything on top of stove. 14. Do not use any solid fuels (wood, coal, paper, card- board, etc.) in this stove. Use only the gas type indi- cated on burner system nameplate. 15. This appliance, when installed, must be electrically grounded in accordance with local codes or in the absence of local codes, with the National Electrical...
  • Page 5: Product Features

    PRODUCT FEATURES CSDV Series Direct Vent Gas Stove PRODUCT SPECIFICATIONS On/Off • This appliance has been certified for use with either Switch natural or propane gas. See appropriate data plates. • This appliance is not for use with solid fuels. • The appliance is approved for bedroom or bedsitting room installations.
  • Page 6: Stove Dimensions

    STOVE DIMENSIONS CSDV Series Direct Vent Gas Stove ⁄ " (673 mm) 21" (533 mm) ⁄ " (724 mm) Figure 2 - Stove Dimensions 586056 CSDV dims 20306757...
  • Page 7: Stove Location

    INSTALLATION INFORMATION CSDV Series Direct Vent Gas Stove STOVE LOCATION • The flow of combustion and ventilation air must not be obstructed. Plan for the installation of your stove. This includes deter- • Minimum clearances to combustibles, side-wall, ceiling, mining where the unit is to be installed, the vent configura- woodwork, and windows must be maintained. Page tion to be used, framing and finishing details, and whether 8, Figure 4 any optional accessories (i.e. blower, wall switch, or remote •...
  • Page 8: Clearances

    CLEARANCES CSDV Series Direct Vent Gas Stove CLEARANCES TO COMBUSTIBLES WARNING The dimensions shown in Figures 4 and 5 are minimum clearances to maintain in installing this heater. Left and right clearances are determined when facing the front of the heater. Follow these instructions carefully to ensure safe installation.
  • Page 9: Alcove Clearances

    CLEARANCES CSDV Series Direct Vent Gas Stove ALCOVE CLEARANCES Figure 5 - Alcove Clearances ALCOVE MINIMUM DIMENSIONS ST1132 Height from Hearth Width Depth alcove clearances MODEL CSDV30 64" (1626 mm) 35" (889 mm) 36" (914 mm) NOTE: Maintain minimum side and back clearances when placing stove in alcove. 20306757...
  • Page 10: Unpacking

    UNPACKING CSDV Series Direct Vent Gas Stove REMOVING UNIT FROM CRATE Hearth 1. Remove two (2) straps. Figure 6 Door 2. Open plastic bag and slide to bottom of unit. Figure 7 3. Lift up on ash lip and pivot down to open control door. Figure 8 4. Lift up on front. Pivot bottom of front out. Remove front. Figure 8 5.
  • Page 11: Venting Installation

    • Unauthorized modification of the venting system. a maximum of 270°. • Installation of any component part not manufactured For two-story applications, firestops are required at each or approved by Vermont Castings Group. floor level. If an offset is needed in the attic, additional pipe • Installation other than permitted by these instruc- and elbows will be required. tions. You may use a chase with a vent termination with exposed pipe on the exterior of the house. Refer to Installing Vent INSTALLATION PLANNING System in a Chase below.
  • Page 12: Installing A Vent System In An Outside Chase

    VENTING INSTALLATION CSDV Series Direct Vent Gas Stove NOTE: When installing in a chase, you should insulate the INSTALLING A VENT SYSTEM IN AN chase as you would the outside walls of your home. This is OUTSIDE CHASE especially important in cold climates. Minimum clearance A chase is a vertical boxlike structure built to enclose between vent pipes and combustible materials such as venting that runs along the outside of a building.
  • Page 13: Termination Location

    † A vent shall not terminate directly above a sidewalk or paved clearances tested and approved by the listing agency. driveway which is located between two single family dwellings and 3. Vermont Castings Group assumes no responsibility for serves both dwellings the improper performance of the appliance when the venting  Only permitted if veranda, porch, deck or balcony is fully open on a system does not meet these requirements.
  • Page 14: Termination Clearances

    VENTING INSTALLATION CSDV Series Direct Vent Gas Stove TERMINATION CLEARANCES Termination Clearances Termination clearances for buildings with combustible and non-combustible exteriors. Termination clearances for buildings with combustible and noncombustible exteriors. Inside Corner Alcove Applications* Outside Corner Combustible 6" (152 mm) Combustible 6" (152 mm) Noncombustible 2" (51 mm) Noncombustible 2"...
  • Page 15: Installation For Horizontal Termination

    VENTING INSTALLATION CSDV Series Direct Vent Gas Stove INSTALLATION FOR HORIZONTAL TERMI- 2. Rigid vent pipes and fittings have special twist-lock connections. Assemble the desired combination of pipe NATION and elbows to the appliance adaptor with pipe seams 1. Determine the route your horizontal venting will take. oriented towards the wall or floor.
  • Page 16: Horizontal Termination Configurations

    VENTING INSTALLATION CSDV Series Direct Vent Gas Stove Vent Opening for Combustible Walls WARNING ⁄ " (241 mm) Do not recess vent termination into any wall. This will cause a fire hazard. ⁄ " non-hardening mastic around outside edge of the standoff (241 mm) instead of the vent cap assembly.
  • Page 17: Installation For Vertical Termination

    VENTING INSTALLATION CSDV Series Direct Vent Gas Stove Table 2: Horizontal Venting Table 3: Horizontal Venting with Two (2) 90° Elbows Maximum Horizontal (H) Minimum Vertical (V) Maximum Horizontal Minimum Vertical (V) (H+H 24" (610 mm) ⁄ " (1334 mm) 24" (610 mm) ⁄ " (1334 mm) 20' (6 m) ⁄ " (2495 mm) 20' (6 m) ⁄...
  • Page 18 VENTING INSTALLATION CSDV Series Direct Vent Gas Stove Table 4: Horizontal Venting with Three (3) 90° Elbows required clearance space. Figure 23. Otherwise, install firestop below the framed hole. The firestop should be Maximum Horizontal installed with no less than three nails per side. Figure (H+H Minimum Vertical (V) 24" (610 mm) ⁄ " (1334 mm) 2.
  • Page 19: Cathedral Ceiling Installation

    VENTING INSTALLATION CSDV Series Direct Vent Gas Stove 4. Using tin snips, cut the support box from the top corners down to the roofline and fold the resulting flaps over the 9 ¹ ⁄ ₂ " ⁄ ₂ " roof sheeting. Figure 26. Apply a bead of non-hardening 9 ¹ mastic around the top edges of the support box to make a seal between the box and the roof.
  • Page 20: Vertical Termaination Configurations

    VENTING INSTALLATION CSDV Series Direct Vent Gas Stove Table 6: Venting with Two (2) 90° Elbows VERTICAL TERMINATION CONFIGURA- TIONS Maximum Horizontal (H+H Minimum Vertical (V) Figures 27 through 29 show four different configurations 24" (610 mm) ⁄ " (1137 mm) for vertical termination. 20' (6 m) ⁄ " (2508 mm) IMPORTANT: Install restrictor as indicated on chart (Figure 13) on Page 14.
  • Page 21: Duravent Gs 4" X 6

    VENTING INSTALLATION CSDV Series Direct Vent Gas Stove DURAVENT GS 4" X 6 ⁄ " (BLACK PIPE) Vertical Venting (V) = 40' (12 m) Maximum Number Description NOTE: Install restrictor into 4" collar of stove or first vent section 902B ⁄ " x 48" Pipe as shown. 903B ⁄ " x 36" Pipe 904B ⁄ " x 24" Pipe 906B ⁄...
  • Page 22: Stove Installation

    STOVE INSTALLATION CSDV Series Direct Vent Gas Stove CHECK GAS TYPE Use proper gas type for the fireplace you are installing. If you have conflicting gas type, do not install fireplace. 100 gal. (min) See dealer where you purchased the fireplace for proper Propane/LP External Supply Tank fireplace according to your gas type. Regulator INSTALL GAS PIPING TO FIREPLACE LOCATION A qualified installer or service person must...
  • Page 23: Check Gas Pressure

    STOVE INSTALLATION CSDV Series Direct Vent Gas Stove NOTE : The gas line connection may be made using 1/2" We recommend that you install a sediment trap/drip leg in rigid tubing or an approved flex connector. Since some supply line as shown in Figure 31. Locate sediment trap/ municipalities have additional local codes it is always best drip leg where it is within reach for cleaning.
  • Page 24: Electrical Installation

    ELECTRICAL INSTALLATION CSDV Series Direct Vent Gas Stove ELECTRICAL WIRING REMOTE WALL MOUNTED SWITCH This stove will work without any electrical supply. Electricity A remote wall switch and up to fifteen (15) feet of 18 Ga. is only needed to operate blower. wire may be used with this appliance. Attach the wall switch in a junction box at the desired location on the NOTE: If installed in mobile home, fireplace must be bolted wall.
  • Page 25: Log And Rock Wool Placement

    LOG AND ROCK WOOL PLACEMENT CSDV Series Direct Vent Gas Stove PLACE CSDV30 LOGS IN FIREBOX 7. Place top right log (#5) on right base log. Line up the notch in the bottom of the top log with the locator pins Figure 34 on the bottom log. BEFORE YOU BEGIN: This unit is supplied with ceramic PLACE ROCK WOOL (EMBER MATERIAL) fiber logs. Do not handle these logs with your bare hands.
  • Page 26: Safety Barrier Installation

    SAFETY BARRIER INSTALLATION CSDV Series Direct Vent Gas Stove DANGER CERTIFIED AFETY ARRIER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS SAFETY BARRIER INSTALLATION UNTIL COOLED. INSTRUCTIONS NEVER ALLOW CHILDREN TO TOUCH GLASS. NOTE: A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this A barrier designed to reduce the risk of burns from the hot appliance and shall be installed for the protection of...
  • Page 27: Operating Instructions

    OPERATING INSTRUCTIONS CSDV Series Direct Vent Gas Stove FOR YOUR SAFETY READ BEFORE LIGHTING If you do not follow these instruction exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with a pilot which must be lit by hand while following these instructions exactly. B.
  • Page 28: Lighting Pilot For The First Time

    OPERATING INSTRUCTIONS CSDV Series Direct Vent Gas Stove LIGHTING PILOT FOR THE FIRST TIME INITIAL LIGHTING If using a soap and water solutiong Purge air from the supply line as follows: to test for leaks, DO NOT spray • Open main shutoff valve. solution onto control body.
  • Page 29: Lighting Burner

    OPERATING INSTRUCTIONS CSDV Series Direct Vent Gas Stove LIGHTING BURNER MAIN BURNER SWITCH The “ON/OFF” switch for the main burner can be found on the back right side of the stove. This switch allows you to turn on and to turn off the main burner without using the gas valve knob. Make sure the button is in the “ON” position to light the main burner. LIGHTING THE BURNER On/Off/RS Switch Depress and turn the knob counterclockwise to the “ON”...
  • Page 30: Air Shutter Adjustment (Natural Gas Only)

    OPERATING INSTRUCTIONS CSDV Series Direct Vent Gas Stove ADJUSTING THE AIR SHUTTER (NG ONLY) The venturi of the burner is equipped with an air shutter. The opening of the venturi has been set at 1/4" for Natural Gas and fully open for Propane installation at sea level. Natural Gas Models may be adjusted for high altitude as follows: • To increase air mixture, pull down the adjustment rod located beneath the stove. This opens the shutter more and will stop sooting.
  • Page 31: Cleaning And Maintenance

    CLEANING AND MAINTENANCE CSDV Series Direct Vent Gas Stove NOTE: Make sure the gas valve knob is in the “OFF” Allow glass to cool before cleaning. position. Wait at least five (5) minutes before start - ing maintenance. Do not clean glass when it is hot. VENTING SYSTEM Damage could occur.
  • Page 32: Replacing Glass

    Slide glass frame back down onto stove and fasten two clamps. Figure 41 Insert front into the top of the stove, and push forward O FF onto the legs. 10. Replace safety barrier. NOTE: Use only original Vermont Castings Group replacement parts. Gasket Glass Glass Frame...
  • Page 33: Troubleshooting

    TROUBLESHOOTING CSDV Series Direct Vent Gas Stove Turn appliance OFF and allow to cool before servicing. Only a qualified service person should service and repair the heater. NOTE: All troubleshooting items are listed in order of operation. PROBLEM POSSIBLE CAUSE REMEDY Spark ignitor will not light the pilot after 1.
  • Page 34: Replacement Parts

    REPLACEMENT PARTS CSDV Series Direct Vent Gas Stove WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. 20306757 586056 CSDV30 parts...
  • Page 35: Replacement Parts

    REPLACEMENT PARTS CSDV Series Direct Vent Gas Stove Ref. Description Qty. CSDV30NV CSDV30PV Burner Assembly 58D0150 58D0150 2. Log Support Bracket 58D0024 58D0024 Pilot Assembly 37D0018 37D0019 4. SIT 820 Nova Valve 37D0117 37D0118 Injector 58D0102 20H3144 Venturi 45D0600 45D0600 7. Valve Tube 58D0163 58D0163 ON/OFF Rocker Switch 41D0048 41D0048 Ceramic Glass...
  • Page 36: Massachusetts Residents Only

    MASSACHUSETTS RESIDENTS ONLY CSDV Series Direct Vent Gas Stove Please read and follow these special requirements NOTE REGARDING VENTED PRODUCTS 2. Approved Carbon Monoxide Detectors. Each carbon This product must be installed by a licensed plumber or gas fitter monoxide detector as required in accordance with the above when installed within the Commonwealth of Massachusetts. provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.
  • Page 37: Warranty

    CSDV Series Direct Vent Gas Stove LIMITED LIFETIME WARRANTY POLICY Vermont Castings Group warrants its products to be free of defects in material and workmanship and backs each product with a Limited Lifetime Warranty. This warranty is to the original purchaser of a Vermont Castings Group product and is not transferable. LIFETIME WARRANTY Covered under this warranty are the stove body, combustion chamber, door frame, gold plating (manufacturing defects only), glass (thermal breakage only), heat exchange system, and burner. This coverage includes parts and reasonable...
  • Page 40 CSDV Series Direct Vent Gas Stove EFFICIENCY RATINGS EnerGuide Ratings Fire- D.O.E. Model place Efficiency (%) (AFUE%) CSDV30NV 65.4 67.4 CSDV30PV 76.1 67.2 Based on CSA P.4.1-09 Recherchez dans la brochure les caractéristique de rendement énergétique de foyer au gaz Énerguide Based on CSA P.4.1-09 Selon CSA P.4.1-09...