Download Print this page

Wolf Sub-Zero BI Series Service Manual page 8

Advertisement

Component Removal
Model BI-36F Interior Cosmetic / Mechanical Components
Door Gasket
A dart at the back of the door gasket fits into metal
channels attached to the inside perimeter of the door.
To remove a door gasket, starting at one corner, pull
the gasket dart from the metal channels. (See Figure
6-93).
Adjustable Door Shelves
Removal and adjustment of the door shelves is
achieved by sliding the grooves in the shelving end-
caps over the molded retaining ribs of the door liner.
Lift out and up to remove, push in and down to install.
(See Figure 6-94).
Cantilever Shelf Assembly
To adjust and/or remove a freezer cantilever wire shelf
assembly (See Figure 6-95):
1. Lift front of shelf up slightly.
2. Lift back of shelf up to disengage the shelf ladder
hooks from the shelf ladders.
3. Pull shelf forward and out of the shelf ladders.
7040317 - Revision A - September, 2015
Built-In (BI) Series
Built-In (BI) Series
Metal Channels
Figure 6-95. Cantilever Shelf Removal
6-38
(SWS #4380000)
(SWS #4380000)
Figure 6-93. Door Gasket Removal
Figure 6-94. Adjustable Door Shelf
1
Gasket
3
2