Download Print this page

Troubleshooting - BEA IXIO-DT1 Manual

Activation & safety sensor for automatic sliding doors
Hide thumbs Also See for IXIO-DT1:

Advertisement

TROUBLESHOOTING

ORANGE LED ashes 1 x.
E1
1
ORANGE LED ashes 2 x.
E2
2
ORANGE LED ashes 4 x.
E4
4
ORANGE LED ashes 5 x.
E5
5
ORANGE LED ashes 8 x.
E8
8
ORANGE LED is on.
RED LED ashes
quickly after an
assisted setup.
RED LED lights up
sporadically.
GREEN LED lights up
sporadically.
The LED and the LCD-
display are o .
The reaction of the door
does not correspond to the
LED-signal.
The LCD or remote
control does not react.
IXIO sensors are intended to be used with pedestrian sliding door systems.
This device can be expected to comply with Part 15 of the FCC Rules provided it is assembled in exact accordance with
the instructions provided with this kit. Operation is subject to the following conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference received including interference that may cause
undesired operation.
Page 6 of 8
The sensor signals an
internal fault.
The power supply is too low
or too high.
The sensor receives
not enough AIR-energy.
The sensor receives too
much AIR-energy.
The sensor is disturbed by
external elements.
IR power emitter is faulty.
The sensor encounters a
memory problem.
The sensor sees the door
during the assisted setup.
The sensor vibrates.
The sensor sees the door.
The sensor is disturbed by
external conditions.
The sensor is disturbed by
rain and/or leaves.
Ghosting created by door
movement.
The sensor vibrates.
The sensor sees the door or
other moving objects.
The sensor is protected by a
password.
Replace sensor.
1
1
Check power supply
(in the diagnostics menu of the LCD).
2
Check wiring.
Decrease the angle of the AIR-curtains.
1
Increase the AIR-immunity lter.
2
Deactivate 1 curtain.
3
1
Slightly increase the angle of the AIR-curtains.
2
Decrease the AIR-immunity lter.
1
Eliminate the cause of disturbance (lamps, rain cover, door
controller housing properly grounded).
1
Replace sensor.
1
Cut and restore power supply.
If orange LED lights up again, replace sensor.
2
Move the AIR-curtains away from the door.
1
2
Install the sensor as close to the door as possible.
If needed, use a bracket accessory.
Launch a new assisted setup.
3
1
Check if the sensor is fastened rmly.
Check position of cable and cover.
2
1
Launch an assisted setup and adjust the IR angle.
1
Increase the AIR-immunity lter.
1
Increase radar-immunity lter.
1
Change radar eld angle.
1
Check if the sensor and door cover is fastened rmly.
2
Check position of cable and cover.
1
Remove the objects if possible.
2
Change radar eld size or angle.
1
Check wiring.
1
Check output con guration setting.
Check wiring.
2
1
Enter the right password. If you forgot the code, cut and
restore the power supply to access the sensor without
entering a password during 1 minute.
75.5751.08 IXIO-DT1 UL 201601220

Advertisement

loading