CHIMNEY CONNECTION

Two basic types of chimneys are approved for use with solid fuel: Factory-built and
masonry. Factory-built chimney must comply with UL103HT standard.
Do not expect your stove or furnace to create draft. Draft is not a function of the
appliance. Draft is purely a function of the chimney. Modern stoves and furnaces
are much more airtight and efficient than those of the past; and, therefore require
greater draft. A minimum of .05, measured in water column (gauges to measure
chimney draft are readily available at stove shops and are economical to purchase
or rent) is required for proper drafting to prevent back-puffing, smoke spillage, and
to maximize performance.
Chimneys perform two functions - one of which is apparent: The chimney provides
a means for exhausting smoke and flue gases resulting from combustion of the fuel.
Secondarily, though, the chimney provides "Draft" which allows oxygen to be
continuously introduced into the appliance, so that proper combustion is possible.
As of April 1, 1987, all heaters and furnaces manufactured by United States Stove
Company should be installed using a factory built chimney that meets the "Type HT"
requirement of UL 103 (when a factory - built chimney is used).
IMPORTANT
*Size the chimney to the flue outlet on the stove. (6" outlet = 6" I.D. chimney)
*Avoid using elbows except as necessary (they reduce draft).
*Make sure all horizontal runs of connector pipe go up hill (1/4" elevation for each
horizontal foot).
FLUE CONNECTION - NON-COMBUSTIBLE WALL
THIMBLE
COLLAR
PIPE
ELBOW
PIPE
NON-COMBUSTIBLE
FLOOR PROTECTOR
WALL

Fig. 5

2 FT MIN.
3 FT.
10 FT.
MIN.
REFER TO CHIMNEY
MANUFACTURERS PARTS
AND INSTRUCTIONS
PIPE
FLOOR PROTECTOR
Fig. 6