Stanley SIG2000-1 Original Instructions Manual page 12

Inverter generator
Table of Contents

Advertisement

Available languages

Available languages

G
B
low-Temperature environment. ( -20 degree to 0 degree)
Dispose of the used oil properly by taking it to a
collection point. Most filling stations, repair garages, and
recycling centers will accept used oil free of charge. Do
not add antifreeze or transmission fluid to the used oil.
Keep used oil out of the reach of children and away from
sources of ignition.
9.3 Automatic oil cut-out
The engine will not start if it does not have enough oil.
If the engine is low on oil while it is running, the oil
warning indicator (Item 13) will light up red and the
engine will stall. The oil indicator goes out when the
engine has come to a complete stop.
The engine oil must be topped up before the engine can
be started again.
9.4 Air filter (Figs. 8-10)
Clean the air filter at regular intervals, and replace it if
necessary. Please also read the service information.
Remove the air filter cover (Item 18).
Remove the air filter (Item 19).
Clean the air filter by tapping it. In cases of stubborn
dirt first clean with soapy water, then rinse with clear
water and air-dry before reinserting. Important: Do not
use abrasive cleaners or petrol to clean the air filter.
Assemble in reverse order.
9.5 Spark plug (Fig. 11-12)
Check the spark plug for wear at regular intervals. Please
also read the service information.
Pull off the spark plug boot (Item 20) by twisting it.
Remove the spark plug (Item 21) using the supplied
spark plug wrench (Item 15).
Clean the spark plug with a copper wire brush or fit a
new one.
Assemble in reverse order.
12

Advertisement

Table of Contents
loading

Table of Contents