Transducer Block Operations - Configuration And Calibration - Emerson ROSEMOUNT 5081-A Instruction Manual

Fieldbus two-wire chlorine, dissolved oxygen, and ozone transmitter
Table of Contents

Advertisement

MODEL 5081-A
6.3 Transducer Block Operations — Configuration and Calibration
6.3.1 Deltav Explorer Transducer Block Interface
1. Context Menu
the deltaV Explorer exposes methods for changing the process variable, zeroing and standardizing the
sensors, calibrating oxygen sensors in air, standardizing the temperature measurement, and standardizing
and buffer calibrating the pH sensor (free chlorine only).
2. transducer Block Properties
the transducer Block Properties Windows allow full configuration of the 5081A-FF. the transducer Block
must be put in the out of Service Mode (ooS) to allow configuration parameters to be changed. the follow-
ing parameters are exposed on each tab:
• Mode Tab: Allows the transducer Block to be switched between the Auto and out of Service Modes.
• Measurement Tab: Shows all of the 5081A-FF live measurements and their status.
• Amperometric Sensor Tab: Contains all of the configuration and calibration parameters for the oxygen,
chlorine, or ozone sensor.
• Temperature Compensation Tab: Contains all of the configuration parameters for temperature compen-
sation and the temperature measurement.
• Identification Tab: Contains serial and revision numbers and the passcode for the infrared remote con-
troller.
• pH Compensation (free chlorine only): Contains all of the configuration, calibration, and diagnostic
parameters for the pH sensor.
OPERATION WITH FOUNDATION FIELDBUS AND THE DELTAv CONTROL SySTEM
SECTION 6.0
37