11. Use screwdriver to orient auger shaft to align with motor
shaft keyway (Fig. 29.1).
12. Install key into keyway (Fig. 29.2).
13. Install spacer, ensure that key is captured in slot
(Fig. 30.1)
14. Insert screwdriver into groove of auger shaft and pry shaft
outwards (Fig. 31.1).
15. Insert retainer into groove (Fig. 31.2), ensure that retainer
is aligned with hole in spacer.
Fig. 29
Fig. 30
Fig. 31
Dispenser and Ice Machine 230 V/50 Hz and 220 V/60 Hz
2
1
1
1
2
21